欢迎访问ic37.com |
会员登录 免费注册
发布采购

GPM130B 参数 Datasheet PDF下载

GPM130B图片预览
型号: GPM130B
PDF下载: 下载PDF文件 查看货源
内容描述: 130瓦的全球绩效切换器 [130 Watt Global Performance Switchers]
分类和应用:
文件页数/大小: 2 页 / 279 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号GPM130B的Datasheet PDF文件第1页  
GPC130 Commercial/GPM130 Medical 130 Watt Multiple Output  
Commercial  
Model  
Medical  
Model  
Output  
Minimum  
Output  
Maximum (B)  
Output  
Total  
Output No.  
Output  
Maximum (C) Output Peak  
Noise P-P Regulation (A)  
GPC130A  
GPC130B  
GPC130C  
GPC130D  
GPC130E  
GPM130A  
GPM130B  
GPM130C  
GPM130D  
GPM130E  
1
2
3
4
+5 V  
+12 V  
-12 V  
+12 V  
3 A  
0 A  
0 A  
0 A  
16 A  
5 A  
1.2 A  
1.2 A  
20 A  
5 A  
1.2 A  
1.2 A  
25 A  
8 A  
1.5 A  
1.5 A  
50 mV  
120 mV  
120 mV  
120 mV  
2%  
2%  
3%  
3%  
1
2
3
4
+ 5 V  
+12 V  
-5 V  
3 A  
0 A  
0 A  
0 A  
16 A  
5 A  
1.2 A  
1.2 A  
20 A  
5 A  
1.2 A  
1.2 A  
25 A  
8 A  
1.5 A  
1.5 A  
50 mV  
120 mV  
50 mV  
2%  
2%  
3%  
3%  
-12 V  
120 mV  
1
2
3
4
+5 V  
+12 V  
-15 V  
+15 V  
3 A  
0 A  
0 A  
0 A  
16 A  
5 A  
1.2 A  
1.2 A  
20 A  
5 A  
1.2 A  
1.2 A  
25 A  
8 A  
1.5 A  
1.5 A  
50 mV  
120 mV  
150 mV  
150 mV  
2%  
2%  
3%  
3%  
1
2
3
4
+5 V  
+24 V  
-12 V  
+12 V  
3 A  
0 A  
0 A  
0 A  
16 A  
3.5 A  
1.2 A  
1.2 A  
20 A  
3.5 A  
1.2 A  
1.2 A  
25 A  
5 A  
1.5 A  
1.5 A  
50 mV  
240 mV  
120 mV  
120 mV  
2%  
2%  
3%  
3%  
1
2
3
4
+5 V  
+24 V  
-15 V  
+15 V  
3 A  
0 A  
0 A  
0 A  
16 A  
3.5 A  
1.2 A  
1.2 A  
20 A  
3.5 A  
1.2 A  
1.2 A  
25 A  
5 A  
1.5 A  
1.5 A  
50 mV  
240 mV  
150 mV  
150 mV  
2%  
2%  
3%  
3%  
A.Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.  
B. Unrestrictednaturalconvectioncooling.  
C. Requires26 cfmmovingair.  
GPC130/GPM130 MECHANICAL SPECIFICATIONS  
Environmental  
Specification  
Operating  
Non-operating  
Temperature (A)  
See individual specs  
0 to 95% RH  
-40 to +85oC  
0 to 95% RH  
40 gpk  
Humidity (A)  
Shock (B)  
Altitude  
A. Units should be allowed to warm up/operate under non-condensing conditions  
before application of power.  
B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3  
orthogonal axes.Tested for 10 min./axis operating and 1 hr./axis non-operating.  
C. Shock testinghalf-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,  
total 6 shocks.  
20 gpk  
-500 to 10,000 ft  
1.5 grms, 0.003 g2/Hz  
-500 to 40,000 ft  
5 grms, 0.026 g2/Hz  
Vibration (C)  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com  
55