GENERAL SPECIFICATIONS
Hold-up time
Efficiency
120 Vac, 60 Hz
30 ms at 600 Watts output
>84 %
120 Vac 600 W output
isolation voltage
input to ouput
input to ground
4000 Vac
1500 Vac
Switching frequency
Safety Approvals
Maximum weight
fixed
70 KHz, +/- 10 KHz
UL/EN/IEC 60950-1 1st Edition CSA22.2 No.60950-1-03
2 kg (4.4 lbs)
MODEL NUMBER Output
Peak Output
Features
Hot Swap
Hot Swap
Hot Swap
Hot Swap
Ripple
Regulation
GPHP600-24
GPHP600-28
GPHP600-36
GPHP700-48
24 V 25 A
24 V 27 A
28 V 23.5 A
36 V 19 A
48 V 15.6 A
240 mV
240 mV
240 mV
240 mV
3% (see note 4)
3% (see note 4)
3% (see note 4)
3% (see note 4)
28 V 21.5 A
36 V 17 A
48 V 14 A
NOTES
1. Integral forced air cooling
2. Peak rating is for 1 minute maximum 10% duty cycle
3. Noise measurent 20 MHz Bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply.
4. Regulation includes provision for ‘droop’ sharing
MECHANICAL NOTES
The GPHP series is factory configured for rack mounting installation with Condor CRA series racks. Other mounting configurations and connector op-
tions are available, Please contact factory.
POWER CONNECTOR DIN # 41612 Type H
INPUT PINS
Z-32
AC Line
D-30
AC Neutral
Z-28, D26
GROUND
OUTPUT PINS
Z12, D14, Z16,D18
OUTPUT
Z4, D6, Z8, D10
RETURN (COMMON)
STATUS & CONTROL PINS
Z20
DC POWER GOOD
INHIBIT
Z24
D22
AC POWER FAIL
Page 2 of 3