Commercial
Model
Output
Minimum (A)
Output
Maximum (A)
Output
Maximum (B)
Total
Regulation
Output No.
Output
5.1 v
12 V
OVP Setpoint
6.2 0.6 V
14 1.1 V
18.5 1.5 V
28 2.5 V
34 2.8 V
55 4 V
Notes
GPFC 110-5
GPFC 110-12
GPFC 110-15
GPFC 110-24
GPFC110-28
GPFC110-48
1
1
1
1
1
1
0 A
0 A
0 A
0 A
0 A
0 A
11 A
6.7 A
5.3 A
3.4 A
2.9 A
1.7 A
15 A
9.2 A
7.3 A
4.6 A
3.9 A
2.3 A
2%
2%
2%
2%
2%
2%
C
C
C
C
C
C
15 V
24 V
28 V
48 V
Notes:
A. With unrestricted convection cooling.
B. With 26cfm airflow.
C. Add “G”suffix to part number for RoHS compliant model.
GPFC110 MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS OPERATING
NON-OPERATING
-40 to +85°C
Temperature (A)
Humidity (A)
Shock (B)
See Individual Specs.
0 to 95% RH
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Shock testing—half-sinusoidal, 10 3 ms duration, direction,
3 orthogonal axes, total 6 shocks.
0 to 95% RH
20 gpk
40 gpk
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
1 hr./axis non-operating.
Altitude
-500 to 10,000 ft
1.5 g rms’0.003 g2/Hz
-500 to 40,000 ft
5 g rms’0.026 g2/Hz
Vibration (C)
SL Power Electronics., 6050 King Drive, Bldg A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com Rev. 8/12 Data Sheet © 2009
SL Power Electronics Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.