Commercial
Model
Medical
Model
Output
Minimum
Output
Maximun
Output
Peak
Total
Regulation (A)
Output No.
Output
Noise P-P
GPC55A
GPM55A
1
2
3
4
+5 V
+12 V
+12 V
-12 V
0.7 A
0 A
6 A
3 A
1 A
1 A
8 A
5 A
1.2 A
1.2 A
50 mV
120 mV
120 mV
120 mV
2%
2%
3%
3%
0 A
0 A
GPC55B
GPC55C
GPC55D
GPC55E
GPC55F
GPM55B
GPM55C
GPM55D
GPM55E
GPM55F
1
2
3
4
+5 V
+12 V
-5 V
0.7 A
0 A
6 A
3 A
1 A
1 A
8 A
5 A
50 mV
120 mV
50 mV
2%
2%
3%
3%
0 A
1.2 A
1.2 A
-12 V
0 A
120 mV
1
2
3
4
+5 V
+15 V
-5 V
0.7 A
0 A
0 A
0 A
6 A
3 A
1 A
1 A
8 A
5 A
1.2 A
1.2 A
50 mV
150 mV
50 mV
2%
2%
3%
3%
-15 V
150 mV
1
2
3
4
+5 V
+24 V
+12 V
-12 V
0.7 A
0 A
0 A
0 A
6 A
1.5 A
1 A
8 A
5 A
1.2 A
1.2 A
50 mV
240 mV
120 mV
120 mV
2%
2%
3%
3%
1 A
1
2
3
4
+5 V
+24 V
+15 V
-15 V
0.7 A
0 A
0 A
0 A
6 A
1.5 A
1 A
8 A
5 A
1.2 A
1.2 A
50 mV
120 mV
150 mV
150 mV
2%
2%
3%
3%
1 A
1
2
3
4
+5 V
+12 V
+15 V
-15 V
0.7 A
0 A
0 A
0 A
6 A
3 A
1 A
1 A
8 A
5 A
1.2 A
11
50 mV
120 mV
150 mV
150 mV
2%
2%
3%
3%
GPC55-5
GPM55-5
1
1
1
1
1
1
5 V
0 A
0 A
0 A
0 A
0 A
0 A
11 A
4.7 A
3.7 A
2.3 A
2.0 A
1.5 A
14 A
5.8 A
4.7 A
2.9 A
2.4 A
1.5 A
50 mV
120 mV
150 mV
240 mV
280 mV
480 mV
2%
2%
2%
2%
2%
2%
GPC55-12
GPC55-15
GPC55-24
GPC55-28
GPC55-48
GPM55-12
GPM55-15
GPM55-24
GPM55-28
12 V
15 V
24 V
28 V
48 V
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Add“G”suffix to model to indicate RoHS compliant moel.
GPC55/GPM55 MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS OPERATING
NON-OPERATING
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
Temperature (A)
Humidity (A)
Shock (B)
See individual Specs -40 to +85°C
0 to 95% RH
20 gpk
0 to 95% RH
40 gpk
B. Shock testing—half-sinusoidal, 10 3 ms duration, direction, 3
orthogonal axes, total 6 shocks.
Altitude
-500 to 10,000 ft
1.5 g rms’0.003 g2/Hz 5 g rms’0.026 g2/Hz
-500 to 40,000 ft
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
Vibration (C)
SL Power Electronics Corp.. 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 5/08.
Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.