Commercial
Model
Medical
Model
Output No.
Output
Output
Minimum
Output
Maximum
Output
Peak
Noise P-P
Total
Regulation
Notes
GPC40A
GPC40B
GPC40D
GPM40A
GPM40B
GPM40D
1
2
3
1
2
3
1
2
3
1
1
1
1
1
1
1
+5.1 V
+12 V
-12 V
+5.1 V
+15 V
-15 V
+5.1 V
+24 V
-12 V
3.3 V
5 V
0.4 A
0 A
0 A
0.4 A
0 A
0 A
0.4 A
0.A
0.A
0
4 A
2 A
5 A
3 A
50 mV
120 mV
120 mV
50 mV
2%
5%
3%
2%
5%
3%
2%
5%
3%
2%
2%
2%
2%
2%
2%
2%
B,C
C
0.4 A
4 A
0.7 A
5 A
2 A
3 A
150 mV
150 mV
50 mV
B,C
C
0.4 A
4 A
0.7 A
5 A
1 A
1.5 A
0.7 A
10 A
10 A
6 A
240 mV
120 mV
35 mV
B,C
C
0.4 A
8 A
GPC40-3.3
GPC40-5
GPM40-3.3
GPM40-5
0
8 A
50 mV
GPC40-9
GPM40-9
9 V
0 A
0 A
0 A
0 A
0 A
4.5 A
3.3 A
2.7 A
1.7 A
1.4 A
90mV
GPC40-12
GPC40-15
GPC40-24
GPC40-28
GPM40-12
GPM40-15
GPM40-24
GPM40-28
12 V
4.2 A
3.3 A
2.1 A
1.8 A
120 mV
150 mV
240 mV
280 mV
15 V
24 V
28 V
Note: For 48 volt model, GPC40-48 or GPM40-48, contact factory for availability.
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. To maintain these regulation conditions, the 5.1V current must be at least 1/4 of V2 and not greater than 5 times the V2 current.
C. Requires +5.1V to be adjusted within 1% with at least a 0.4A load to maintain regulation on this output.
D. Add “G”suffix to model number for RoHS compliant model.
GPC40/GPM40 MECHANICAL SPECIFICATIONS
3
3
A. Units should be allowed to warm up/operate under non-condensing
ENVIRONMENTAL SPECIFICA-
OPERATING
NON-OPERATING
onditions before application of power.
B. Shock testing—half-sinusoidal, 10 3 ms duration, direction,
3 orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
1 hr./axis non-operating.
TIONS
Temperature (A)
Humidity (A)
Shock (B)
See individual specs. -40 to +85°C
0 to 95% RH
0 to 95% RH
40 gpk
20 gpk
Altitude
-500 to 10,000 ft
1.5 g rms’0.003 g2/Hz
-500 to 40,000 ft
5 g rms’0.026 g2/Hz
Vibration (C)
SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com. Rev. 1/07.