Commercial  
Model  
Medical  
Model  
Output No.  
Output  
Output  
Minimum  
Output  
Maximum  
Output  
Peak  
Noise P-P  
Total  
Regulation  
Notes  
GPC40A  
GPC40B  
GPC40D  
GPM40A  
GPM40B  
GPM40D  
1
2
3
1
2
3
1
2
3
1
1
1
1
1
1
1
+5.1 V  
+12 V  
-12 V  
+5.1 V  
+15 V  
-15 V  
+5.1 V  
+24 V  
-12 V  
3.3 V  
5 V  
0.4 A  
0 A  
0 A  
0.4 A  
0 A  
0 A  
0.4 A  
0.A  
0.A  
0
4 A  
2 A  
5 A  
3 A  
50 mV  
120 mV  
120 mV  
50 mV  
2%  
5%  
3%  
2%  
5%  
3%  
2%  
5%  
3%  
2%  
2%  
2%  
2%  
2%  
2%  
2%  
B,C  
C
0.4 A  
4 A  
0.7 A  
5 A  
2 A  
3 A  
150 mV  
150 mV  
50 mV  
B,C  
C
0.4 A  
4 A  
0.7 A  
5 A  
1 A  
1.5 A  
0.7 A  
10 A  
10 A  
6 A  
240 mV  
120 mV  
35 mV  
B,C  
C
0.4 A  
8 A  
GPC40-3.3  
GPC40-5  
GPM40-3.3  
GPM40-5  
0
8 A  
50 mV  
GPC40-9  
GPM40-9  
9 V  
0 A  
0 A  
0 A  
0 A  
0 A  
4.5 A  
3.3 A  
2.7 A  
1.7 A  
1.4 A  
90mV  
GPC40-12  
GPC40-15  
GPC40-24  
GPC40-28  
GPM40-12  
GPM40-15  
GPM40-24  
GPM40-28  
12 V  
4.2 A  
3.3 A  
2.1 A  
1.8 A  
120 mV  
150 mV  
240 mV  
280 mV  
15 V  
24 V  
28 V  
Note: For 48 volt model, GPC40-48 or GPM40-48, contact factory for availability.  
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.  
B. To maintain these regulation conditions, the 5.1V current must be at least 1/4 of V2 and not greater than 5 times the V2 current.  
C. Requires +5.1V to be adjusted within 1% with at least a 0.4A load to maintain regulation on this output.  
D. Add “Gsuffix to model number for RoHS compliant model.  
GPC40/GPM40 MECHANICAL SPECIFICATIONS  
3
3
A. Units should be allowed to warm up/operate under non-condensing  
ENVIRONMENTAL SPECIFICA-  
OPERATING  
NON-OPERATING  
onditions before application of power.  
B. Shock testing—half-sinusoidal, 10 3 ms duration, direction,  
3 orthogonal axes, total 6 shocks.  
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to  
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and  
1 hr./axis non-operating.  
TIONS  
Temperature (A)  
Humidity (A)  
Shock (B)  
See individual specs. -40 to +85°C  
0 to 95% RH  
0 to 95% RH  
40 gpk  
20 gpk  
Altitude  
-500 to 10,000 ft  
1.5 g rms0.003 g2/Hz  
-500 to 40,000 ft  
5 g rms0.026 g2/Hz  
Vibration (C)  
SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com. Rev. 1/07.  
Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.  
However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.