CAUTION: When performing Dielectric Strength Tests, catastrophic failure of the unit may result if a  
Dielectric Strength test voltage greater than 1800 V ac is applied between primary and secondary  
circuits. The components providing isolation from primary to secondary cannot be tested while installed  
in the power supply without overstressing basic (primary to ground) insulation. All isolating  
components are individually 100 % tested at 4800 V ac prior to installation.  
ISOLATION: The creepage distance between primary and ground is 4 mm minimum; between primary  
and secondary circuits is 8 mm minimum. Secondary to ground creepage is not defined or controlled.  
The output common is bypassed to ground using a 1000 pF, “Y” capacitor. The required creepage and  
clearance distances from primary circuits to ground and secondary circuits must be maintained after  
installation to preserve the intended safety.  
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in  
the applicable safety standards, must not be exceeded after installation to preserve the intended safety.  
The output power, ambient air temperature and the availability, amount, direction and/or restriction of  
airflow influence the temperatures of these components.  
OVERCURRENT PROTECTION: Fuses for both Line and Neutral are provided in the power supply.  
NOTE: For use in permanently installed equipment, remove Fuse F2 and replace with a jumper wire.  
WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit  
component(s). Refer to fuse marking on the power supply for rating. Repair must be performed by  
SLPE authorized personnel.  
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring  
traces and heatsinks.  
EXPLANATION OF SYMBOLS  
Alternating Current  
Attention, Consult  
Accompanying Documents  
Attention, Dangerous Voltages  
Earth (Ground)  
C O N N E C T I O N S  
J1 Pin AC Input  
J2 Pin DC Output  
MATING CONNECTORS  
J1 Amp Housing 640250-3 Contact 770476-1  
J2 Amp Housing 640250-4 Contact 770476-1  
1
3
Line  
Neutral  
1
2
3
4
Output (+)  
Output (+)  
Return  
Return  
SLPE will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of  