GENERAL SPECIFICATIONS
Hold-up time
Efficiency
120 Vac, 60 Hz
16 ms at 30 Watts output
>78 %
120 Vac 30 W output
isolation voltage
input to ouput
input to ground
4000 Vac
1500 Vac
Switching frequency
Safety Approvals
fixed
120 KHz, +/- 5 KHz
UL/EN/IEC 60601-1 CSA22.2 No.601
UL/EN/IEC 60950-1 CSA22.2 No.60950-1
Maximum weight
100 g (0.22 lbs)
MODEL NUMBER 40oC Convection 50oC Convection 50oC Airflow
RIPPLE
REGULATION
GNT30-5
5 V 4.0 A
5 V 3.2 A
5 V 6.0 A
50 mV
2%
2%
2%
2%
2%
2%
GNT30-12
GNT30-15
GNT30-24
GNT30-28
GNT30-48
12 V 2.5 A
15 V 2.0 A
24 V 1.25 A
28 V 1.07 A
48 V 0.625 A
12 V 1.66 A
15 V 1.06 A
24 V 0.83 A
28 V 0.8 A
48 V 0.416 A
12 V 2.5 A
15 V 2.0 A
24 V 1.25 A
28 V 1.07 A
120 mV
150 mV
240 mV
280 mV
48 V 0.625 A 480 mV
NOTES
1. When the input voltage is less than 90 Vac the operating temperature range is 0oC to 40oC. The ripple and regulation
specs. may not be met.
2. Peak output current rating is for 1 minute and 10 % duty cycle.
3. Heatsink temperatures should not be allowed to exceed 90 oC
4. Output Voltage is adjustable +/- 5% of nominal. See installation instructions (www.condorpower.com)
MECHANICAL NOTES
INPUT
J1 AMP P/N 640456-3 TB1
PIN 1 AC LINE
PIN 1 AC LINE
PIN 2 N/C
PIN 2 AC NEUTRAL
GROUND
PIN 3 AC NEUTRAL
0.187 Faston GROUND
OUTPUT J2 AMP P/N 640456-4 TB2
PIN 1 COMMON
PIN 2 COMMON
PIN 3 OUTPUT 1
PIN 4 OUTPUT 1
PIN 1 COMMON
PIN 2 OUTPUT 1
MATING CONNECTORS CONTACT
INPUT
HOUSING 1375820-3
1375819-1
OUTPUT
HOUSING 1375820-4
1375819-1
Condor DC Power Supplies Inc. 2311 Statham Parkway, Oxnard CA, 93033, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: condor@condordc.com
GNT30 Rev H 11/11/05.
Data Sheet © 2005 Condor DC Power Supplies Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Condor accepts no
responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.