GNT200
Front End Series 200W AC/DC
Universal Input Power Supply
2 Year Warranty
Model
Number
Volts (V) ┌──── ────── Output Current ─────────────┐
100Vac Convection 240Vac Convection 90-270VAC Fan Cooled
Ripple
& Noise
Total
Regulation
OVP
Threshold
GNT212G
GNT215G
GNT218G
GNT224G
GNT228G
GNT236G
GNT248G
12V
15V
18V
24V
28V
36V
48V
8.3A
6.7A
5.6A
4.2A
3.6A
2.5A
1.9A
12.5A
10.0A
8.3A
6.3A
5.4A
3.9A
2.9A
16.7A
13.3A
11.1A
8.3A
7.1A
5.6A
4.2A
120mV
150mV
180mV
240mV
280mV
360mV
480mV
2%
2%
2%
2%
2%
2%
2%
14.0 1V
17.6 1V
20.8 1V
27.5 1V
32.0 1V
42.0 1V
55.0 1V
Notes
1.
2.
:
When the input voltage is <90Vac, derate output power by approximately 20%.
Convection ratings shown are for 40°C ambient. Derate load 2.5%/°C to 70°C.
Fan cooled rating of 200W @ 50°C requires 200lfm of airflow over the unit.
3.
General Specifications (continued from p. 1)
Signals
PS Off:
Inhibit:
Pwr OK:
Pwr OK:
DC OK:
High to Inhibit
Low to Inhibit
Goes high 100ms to 200 ms after DC OK signal
Power fail low – 4ms warning
High when output is >92% of nominal
12Vdc @ 250mA
Aux. Output:
Aux. Output:
5Vdc @ 100mA, always on
EMC/EMI Compliance
Conducted Emissions:
Line Freq. Harmonics:
Voltage Fluctuations:
Static Discharge:
EN55011/22, Class B; FCC Class B
EN61000-3-2 Class A
EN61000-3-3
EN61000-4-2
RF Field Susceptability:
Fast Transients/Bursts EFT:
Surge Susceptability:
EN61000-4-3 3 V/meter
EN61000-4-4, 2 kV, 5 kHz – criteria B
EN61000-4-5, criteria B
EN61000-4-6, 3 Vrms
Conducted Immunity:
Power Freq. Mag. Field:
Voltage Dips Immunity:
EN61000-4-8, 3 A/m
EN61000-4-11 Contact factory
GNT200 Series Typical Holdup & Warning Time vs Output Power
200
180
160
140
120
100
80
Tholdup (mS)
Twarning (mS)
60
40
20
0
200
150
100
50
25
Output Power
______________________________________________________________________________________________________________________________ 2 of 3
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: info@slpower.com • www.slpower.com