GLC75 Commercial/GLM75 Medical 75 Watt Single Output
Commercial
Model
Medical
Model
Output
Minimum
Output Maximum Output Maximum
Output
Peak
Total
Regulation
Output
(A)
(B)
V1 OVP Set
6.2 ± 0.6 V
Noise P-P
50 mV
GLC75-5
GLM75-5
5.1 V
12 V
15 V
24 V
28 V
0 A
0 A
0 A
0 A
0 A
13.7 A
19.6 A
21 A
9.5 A
7.7 A
5 A
1%
1%
1%
1%
1%
GLC75-12
GLC75-15
GLC75-24
GLC75-28
GLM75-12
GLM75-15
GLM75-24
GLM75-28
6.3 A
5 A
9.1 A
7.3 A
4.6 A
4 A
15.6 ± 1.1 V
18.5 ± 1.5 V
28 ± 2.5 V
34 ± 2.8 V
120 mV
150 mV
240 mV
280 mV
3.1 A
2.7 A
4.4 A
A. Rating with unrestricted convection cooling. Total power not to exceed 75 W.
B. Rating with 26 cfm forced-air cooling. Total power not to exceed 110 W.
GLC75/GLM75 MECHANICAL SPECIFICATIONS
Environmental
Specification
Operating
Non-operating
Temperature (A)
0 to 50oC
0 to 95% RH
20 gpk
-40 to +85oC
0 to 95% RH
40 gpk
Humidity (A)
Shock (B)
Altitude
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes.Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
total 6 shocks.
-500 to 10,000 ft
1.5 grms, 0.003 g2/Hz
-500 to 40,000 ft
5 grms, 0.026 g2/Hz
Vibration (C)
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com