GLM65AG 参数 Datasheet PDF下载

GLM65AG图片预览
型号: GLM65AG
PDF下载: 下载PDF文件 查看货源
内容描述: [AC-DC Regulated Power Supply Module, 65W]
分类和应用: 输出元件
文件页数/大小: 2 页 / 271 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号GLM65AG的Datasheet PDF文件第1页  
Commercial  
Model  
Medical  
Model  
Output  
Maximum (A)  
Output  
Maximum (B)  
Total  
Regulation (E)  
V1 Adjustment  
Note (C)  
OVP Set-  
point  
Ripple/  
Noise  
Output No.  
Output  
GLC65A  
GLC65B  
GLC65D  
GLC65E  
GLC65G  
GLC65H  
Notes:  
GLM65A  
GLM65B  
GLM65D  
GLM65E  
GLM65G  
GLM65H  
1
2
3
+5.0 V  
+12 V  
-12 V  
7 A  
3 A  
9A  
5 A  
4 A  
2%  
5%  
6%  
5%  
6.2 0.6 V  
1%  
1%  
1%  
2.5 A  
1
2
3
+5.1 V  
+15 V  
-15 V  
7 A  
2.5 A  
2 A  
9 A  
4 A  
3 A  
2%  
4%  
5%  
5%  
6.2 0.6 V  
1%  
1%  
1%  
1
2
3
+5.0 V  
+24 V  
-12 V  
7 A  
1.5 A  
2.5 A  
9 A  
2.5 A  
4 A  
2%  
3%  
6%  
5%  
6.2 0.6 V  
1%  
1%  
1%  
1
2
3
+5.0 V  
+24 V  
+12 V  
7 A  
1.5 A  
2.5 A  
9 A  
2.5 A  
4 A  
2%  
3%  
6%  
5%  
6.2 0.6 V  
1%  
1%  
1%  
1
2
3
+5.0 V  
+3.3 V  
+12 V  
5 A  
4 A  
2.5 A  
8 A  
5 A  
4 A  
3%  
3%  
6%  
5%  
6.2 0.6 V  
1%  
1%  
1%  
1
2
3
+3.3 V  
+5.0 V  
+12 V  
5 A  
4 A  
2.5 A  
8 A  
6 A  
3 A  
3.5%  
4.5%  
6%  
5%  
4.3 0.8 V  
1%  
1%  
1%  
A. Continuous individual output ratings for unrestricted convection cooling. Combination of individual output loads must not exceed total power rating.  
B. Peak rating for 60 s 10% duty cycle or continuous rating 150 LFM forced air cooling.  
C. Adjustment on V1 varies all outputs simultaneously (1% on V1 @ 1% on V2 & V3).  
D. Total combined current of V1 & V2 not to exceed 12 A. Combination of individual output loads must not exceed total power rating.  
E. Total regulation is defined as maximum deviation from the initial set point. With all other outputs at 50% load, output under test can be varied from 0 to 100% load  
and varied to any ac line voltage. Initial set point is 1% on V1, 2% on V2 and 3% on V3  
F. Add “Gsuffix to model number for RoHS compliant model.  
GLC65 MECHANICAL SPECIFICATIONS  
1.20 30.28  
A. Units should be allowed to warm up/operate under non-condensing con-  
ditions before application of power. Derate output current and total output  
power by 2.5% per °C above 50°C. For operation in a confined space, moving  
air may be required. Under all conditions, the cooling vs. load profile should  
be such that heat sinks and/or heatsink temperatures do not exceed 90 °C  
ENVIRONMENTAL SPECIFICATIONS OPERATING  
NON-OPERATING  
-40 to +85°C  
0 to 95% RH  
40 gpk  
for extended periods.  
Temperature (A)  
Humidity (A)  
Shock (B)  
0 TO 50°C  
B. Shock testing—half-sinusoidal, 10 3 ms duration, direction, 3 orthogo-  
nal axes, total 6 shocks.  
0 to 95% RH  
20 gpk  
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz,  
3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-op-  
erating.  
Altitude  
-500 to 10,000 ft  
-500 to 40,000 ft  
Vibration (C)  
1.5 g rms0.003 g2/Hz 5 g rms0.026 g2/Hz  
SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 09/10/08. Data Sheet ©  
2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.  
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.