Commercial
Model
Medical
Model
Output
Current
Total
Regulation
V1 Adjustment
V1 OVP Setpoint
Ripple
and Noise
GLC65-5
GLM65-5
5.1 V
12 V
15 V
18 V
20V
9/11 A *
5.5 A
2%
2%
2%
2%
2%
2%
2%
2%
5%
5%
5%
5%
5%
5%
5%
5%
6.2 0.6 V
14 1.1 V
18.5 1.5 V
21.7 2.0 V
24.5 2.2 V
28 2.5 V
34 2.8 V
55 4.0 V
1%
1%
1%
1%
1%
1%
1%
1%
GLC65-12
GLC65-15
GLC65-18
GLC65-20
GLC65-24
GLC65-28
GLC65-48
GLM65-12
GLM65-15
GLM65-18
GLM65-20
GLM65-24
GLM65-28
GLM65-48
4.3 A
3.6 A
3.25 A
2.7 A
24 V
28 V
48 V
2.3 A
1.35 A
• Note:
* 9 A convection, 11 A with fan cooling
GLC65/GLM65 - SINGLE OUTPUT - MECHANICAL SPECIFICATIONS
1.20 30.28
ENVIRONMENTAL SPECIFICATIONS OPERATING
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 gpk
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derate output current and total
output power by 2.5% per °C above 50°C.
Temperature (A)
Humidity (A)
Shock (B)
0 to 50°
0 to 95% RH
20 gpk
B. Shock testing—half-sinusoidal, 10 3 ms duration, direction, 3
orthogonal axes, total 6 shocks.
Altitude
-500 to 10,000 ft
1.5 g rms’0.003 g2/Hz 5 g rms’0.026 g2/Hz
-500 to 40,000 ft
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1hr./
axis non-operating.
Vibration (C)
SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 01/07.
Data Sheet © 2007 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.