欢迎访问ic37.com |
会员登录 免费注册
发布采购

GLM50-3.3 参数 Datasheet PDF下载

GLM50-3.3图片预览
型号: GLM50-3.3
PDF下载: 下载PDF文件 查看货源
内容描述: [Power Supply Module]
分类和应用: 输出元件
文件页数/大小: 2 页 / 222 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号GLM50-3.3的Datasheet PDF文件第1页  
Commercial  
Model  
Medical  
Model  
Minimum  
Load (B)  
Total  
Regulation (A)  
Output No.  
Output  
+5.05 V  
+12 V  
-12 V  
+5.05 V  
+15 V  
-15 V  
+5.05 V  
+24 V  
-12 V  
+3.3 V  
+12 V  
-12 V  
3.3 V  
Current  
4 A  
OVP Setpoint  
6.2 0.6 V  
Noise P-P  
50 mV  
GLC50A  
GLC50B  
GLC50D  
GLC50G  
GLM50A  
GLM50B  
GLM50 D  
GLM50G  
1
2
3
1
2
3
1
2
3
1
2
3
1
1
1
1
1
1
1
0.8 A  
0.8 A  
0.8 A  
0.8 A  
2%  
+10%,-5%  
3%  
2.5 A  
0.2 A  
4 A  
120 mV  
120 mV  
50 mV  
6.2 0.6 V  
6.2 0.6 V  
4.2 0.6 V  
2%  
2.5 A  
0.2 A  
4 A  
150 mV  
150 mV  
50 mV  
+10%,-5%  
3%  
2%  
1.5 A  
0.2 A  
4 A  
240 mV  
120 mV  
33 mV  
+10%,-5%  
3%  
2%  
2.5 A  
0.2 A  
8 A  
120 mV  
120 mV  
66 mV  
+10%-5%  
3%  
GLC50-3.3  
GLC50-5  
GLM50-3.3  
GLM50-5  
0.2  
0.4  
4.2 0.6 V  
6.2 0.6 V  
14 1.1 V  
18.5 1.5 V  
28 2.5 V  
34.5 2.8 V  
54 3.0 V  
2%  
5.1 V  
8 A  
75 mV  
2%  
GLC50-12  
GLC50-15  
GLC50-24  
GLC50-28  
GLC50-48  
Notes:  
GLM50-12  
GLM50-15  
GLM50-24  
GLM50-28  
GLM50-48  
12 V  
4.2 A  
3.3 A  
2.1 A  
1.8 A  
1.1 A  
0.2  
120 mV  
150 mV  
240 mV  
280 mV  
480 mV  
2%  
15 V  
0.16  
0.1  
2%  
24 V  
2%  
28 V  
0.09  
0.05  
2%  
48 V  
2%  
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.  
B. To maintain specified regulation on multi-output models, output #1 load power must be at least 1/5th of, and not greater than 5 times output #2 load power.  
C. Add “Gsuffix to model number for RoHS compliant model.  
GLC50 MECHANICAL SPECIFICATIONS  
ENVIRONMENTAL SPECIFICATIONS OPERATING  
NON-OPERATING  
-40 to +85°C  
0 to 95% RH  
40 gpk  
Temperature (A)  
Humidity (A)  
Shock (B)  
0 TO 50°C  
A. Units should be allowed to warm up/operate under non-condensing condi-  
tions before application of power. derate output current and total output  
power by 2.5% per °C above 50°C.  
0 to 95% RH  
20 gpk  
B. Shock testing—half-sinusoidal, 10 3 ms duration, direction, 3 orthogonal  
axes, total 6 shocks.  
Altitude  
-500 to 10,000 ft  
-500 to 40,000 ft  
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3  
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.  
Vibration (C)  
1.5 g rms0.003 g2/Hz 5 g rms0.026 g2/Hz  
SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com. Rev. 1/07.  
Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.  
However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.