GLD140 Medical Switchers 140 Watt Multiple Output
Medical
Model
Output
No.
Output
Voltage
Output
Current (A)
Output
Current (B)
Set
Tolerance
Line
Load
OVP
Trip
Ripple
and Noise
GLD140A
1
2
3
4
+5.0 V
+12 V
12 V (C)
-12 V
16 A
6 A
4 A
20 A
8 A
5 A
1%
1%
1%
1%
1%
1%
1%
6.2 ± 0.3 V
14 ± 0.7 V
14 ± 1.2 V
-------
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
0.75 A
1.2 A
2.2%
GLD140B
GLD140C
GLD140D
1
2
3
4
1
2
3
4
+5.0 V
+12 V
5 V (C)
-12 V
+5.0 V
+12 V
15 V (C)
-15 V
16 A
6A
4 A
0.75
16 A
6 A
20 A
8 A
5 A
1.2 A
20 A
8 A
1%
1%
1%
2.2%
1%
1%
1%
2.2%
1%
1%
1%
1%
1%
1%
1%
1%
6.2 ± 0.3 V
14 ± 0.7 V
6.3 ± .5 V
-------
6.2 ± 0.3 V
14 ± 0.7 V
18 ± 1.2 V
-------
4 A
0.75 A
5 A
1.2 A
1
2
3
4
+5.0 V
+24 V
12 V (C)
-12 V
16 A
4 A
4 A
20 A
6 A
5 A
1%
1%
1%
1%
1%
1%
1%
6.2 ± 0.3 V
27 ± 1 V
14 ± 1.2 V
-------
1%
1%
1%
1%
0.75
1.2 A
2.2%
GLD140E
GLD140F
GLD140G
1
2
3
4
+5.0 V
+24 V
15 V (C)
-15 V
16 A
4 A
4 A
20 A
6 A
5 A
1%
1%
1%
1%
1%
1%
1%
6.2 ±0.3 V
27 ± 1 V
18 ± 1.2 V
-------
1%
1%
1%
1%
0.75 A
1.2 A
2.2%
1
2
3
4
+5.0 V
+15 V
12V (C)
-12 V
16 A
5 A
4 A
20 A
7 A
5 A
1%
1%
1%
1%
1%
1%
1%
6.2 ± 0.3 V
18 ± 1.2 V
14 ± 1.2 V
-------
1%
1%
1%
1%
0.75 A
1.2 A
2.2%
1
2
3
4
+5.0 V
+3.3 V
12 V (C)
-12 V
16 A
10 A
4 A
20 A
12 A
5 A
1%
1%
1%
1%
1%
1%
1%
6.2 ± 0.3 V
4.2 ± 0.4 V
14 ± 1.2 V
-------
1%
1%
1%
1%
0.75 A
1.2 A
2.2%
Output Current for Individual Outputs:
A. Output current for unrestricted natural convection.
B. Output current with 150 LFM forced air convection or peak current rating.
C. Isolated (floating) output may be referenced positive or negative.
GLD140 MECHANICAL SPECIFICATIONS
INPUT: JI
MOLEX P.C.B.HEADER P/N 39-30-2056
PIN 1) AC GROUND
PIN 2) N/C
PIN 3) AC NEUTRAL
PIN 4) N/C
PIN 5) AC LINE
MATING CONNECTOR MOLEX P/N:
HOUSING 39-01-4051, CONTACT 39-00-0164
SIGNALS: J2
AMP P.C.B. HEADER P/N:641215-6
PIN 1) +SENSE
PIN 2) -SENSE
PIN 3) POWER FAIL
PIN 4) POWER GOOD
PIN 5) COMMON
PIN 6) INHIBIT
MATING CONNECTOR AMP P/N:
HOUSING 770602-6, CONTACT 770666-2
OUTPUT: J3
MOLEX P.C.B.HEADER P/N: 39-29-9206
PINS 1) +V3out
PINS 2) -V4out
PINS 3,12,13) COMMON
PINS 4) +V2 SENSE
PINS 5,14,15) +V2out
PINS 6-8, 16) COMMON
PINS 9,10,19,20) +V1out
PINS 11) +V3 RTN
PINS 17,18) COMMON
MATING CONNECTOR MOLEX P/N:
HOUSING 39-01-2200, CONTACT 39-00-0164
FAN: J5
AMP P.C.B.HEADER P/N 641215-2
PINS 1) FAN RTN
PINS 2) +FAN
MATING CONNECTOR AMP P/N:
HOUSING 770602-2, CONTACT 770666-2
Environmental
Operating
Non-operating
Specification
Temperature (A)
Humidity (A)
Shock (B)
0 to 50oC
0 to 95% RH
20 gpk
-40 to +85oC
0 to 95% RH
40 gpk
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes.Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
total 6 shocks.
Altitude
-500 to 10,000 ft
1.5 grms, 0.003 g2/Hz
-500 to 40,000 ft
5 grms, 0.026 g2/Hz
Vibration (C)
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
59