GLC50 Commercia/GLM50 Medical 50Watt Multiple Output
Commercial
Model
Medical
Model
Total
Regulation (A)
Output No.
Output
Current
Minimum Load
0.8 A
OVP Setpoint
6.2 ± 0.6 V
Noise P-P
GLC50A
GLC50B
GLC50D
GLC50G
GLM50A
GLM50B
GLM50D
GLM50G
1
2
3
+5.05 V
+12 V
-12 V
4 A
2.5 A
0.2 A
50 mV
120 mV
120 mV
2%
+10%, -5%
3%
1
2
3
+ 5.1 V
+15 V
-15 V
4 A
2.5 A
0.2 A
0.8 A
0.8 A
0.8 A
6.2 ± 0.6 V
6.2 ± 0.6 V
4.2 ± 0.6 V
50 mV
150 mV
150 mV
2%
+10%, -5%
3%
1
2
3
+5.1 V
+24 V
-12 V
4 A
1.5 A
0.2 A
50 mV
240 mV
120 mV
2%
+10%, -5%
3%
1
2
3
+3.3 V
+12 V
-12 V
4 A
2.5 A
0.2 A
33 mV
120 mV
120 mV
2%
+10%, -5%
3%
GLC50-3.3
GLC50-5
GLM50-3.3
GLM50-5
1
1
1
1
1
1
1
3.3 V
5.1 V
12 V
15 V
24 V
28 V
48 V
8 A
0
0
0
0
0
0
0
4.2 ± 0.6 V
6.2 ± 0.6 V
14 ± 1.1 V
18.5 ± 1.5 V
28 ± 2.5 V
34.5 ± 2.8 V
54 ± 3.0 V
33 mV
50 mV
2%
2%
2%
2%
2%
2%
2%
8 A
GLC50-12
GLC50-15
GLC50-24
GLC50-28
GLC50-48
GLM50-12
GLM50-15
GLM50-24
GLM50-28
GLM50-48
4.2 A
3.3 A
2.1 A
1.8 A
1.1 A
120 mV
150 mV
240 mV
280 mV
480 mV
A. Totalregulationisdefinedasthemaximumdeviationfromthenominalvoltageforallsteady-stateconditionsofinitialvoltagesetting, inputlinevoltageandoutputload.
GLC50/GLM50 MECHANICAL SPECIFICATIONS
4.25 [107.95mm]
INPUT J1:
AMP P/N 640445-3, 0.156 CTR 0.045
SQUARE PIN HEADER
4.00 [101.60mm]
0.125
[3.18mm]
PIN 3) AC NEUTRAL
PIN 2) NO PIN
PIN 1) AC LINE
A2
OUTPUT J2:
AMP P/N 640445-6, 0.156 CTR 0.045
SQUARE PIN HEADER
2.50
[63.50mm]
J1
MULTIPLE OUTPUT
PIN 1) OUTPUT #2
PIN 2) OUTPUT #1
PIN 3) OUTPUT #1
PIN 4) COMMON
PIN 5) COMMON
PIN 6) OUTPUT #3
SINGLE OUTPUT
PIN 1-3) OUTPUT
PIN 4-6) RETURN
T2
2.25
[57.15mm]
F1
C4
MATING CONNECTORS: AMP P/N
HOUSING
INPUT
OUTPUT
644329-3
644329-6
0.125
[3.18mm]
NOTE: 5A MAXIMUM RECOMMENDED
CURRENT PER CONNECTOR PIN
1.25" [31.75mm]
MOUNTING HOLE
WEIGHT: 5 OZ. [0.142 KG]
0.138 TYP.
[3.51mm]
TOLERANCES: X.XX=0.030 [0.76mm]
X.XXX=0.010 [0.25mm]
MAX. LEAD PROTRUSION 0.10" [2.54mm]
MAX. COMPONENT HEIGHT 1.15" [29.21mm]
Environmental
Operating
Non-operating
Specification
Temperature (A)
Humidity (A)
Shock (B)
See individual specs
0 to 95% RH
-40 to +85ºC
0 to 95% RH
40 gpk
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
total 6 shocks.
20 gpk
Altitude
-500 to 10,000 ft
1.5 grms, 0.003 g2/Hz
-500 to 40,000 ft
5 grms, 0.026 g2/Hz
Vibration (C)
Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc.
2311 Statham Parkway, Oxnard, CA 93033 • 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com