欢迎访问ic37.com |
会员登录 免费注册
发布采购

GLC110-24 参数 Datasheet PDF下载

GLC110-24图片预览
型号: GLC110-24
PDF下载: 下载PDF文件 查看货源
内容描述: 110瓦的全球绩效切换器 [110 Watt Global Performance Switchers]
分类和应用:
文件页数/大小: 2 页 / 309 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号GLC110-24的Datasheet PDF文件第1页  
Commercial
Model
GLC110-212
GLC110-215
GLC110-524
GLC110-12
GLC110-15
GLC110-24
Medical
Model
GLM110-212
GLM110-215
GLM110-524
GLM110-12
GLM110-15
GLM110-24
RoHS
Suffix*
G
G
G
G
G
G
Output
No.
1
2
1
2
1
2
1
1
1
Output
+12 V
-12 V
+15 V
-15 V
+24 V
+5 V
12 V
15 V
24 V
Output
Minumum
1A
0A
1A
0A
1A
0A
0A
0A
0A
Output
Normal (A)
6.3 A
2.5 A
5A
2.5 A
3.2 A
1.5 A
6.3 A
5A
3.2 A
Forced Air
(B)
9.1 A
3A
7.3 A
3A
4.6 A
2A
9.1 A
7.3 A
4.6 A
Output Peak
9.5 A
4A
7.7 A
4A
4.75 A
2.5 A
9.5 A
7.7 A
5A
Noise P-P
100 mV
120 mV
120 mV
150 mV
200 mV
50 mV
120 mV
150 mV
240 mV
OVP
15.6 ± 1.1 V
18.5 ± 1.5 V
28 ± 2.5 V
6.2 ± 0.6 V
15.6 ± 1.1 V
18.5 ± 1.5 V
28 ± 2.5 V
Total Regu-
lation ( C )
2%
2%
2%
2%
2%
2%
2%
2%
2%
* Add “G” suffix to part number for RoHS compliant model. Contact factory for availability.
A. Rating with unrestricted convection cooling. Total power not to exceed 75 W; no output can exceed rated current.
B. Rating with 26 cfm forced air cooling. Total power not to exceed 110 W.
C. To maintain regulation V1 current must be at least 1/5 of V2. V1 must not be adjusted more than 1% below nominal and have at least 10% of rated load.
GLC110/GLM110 MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (C)
Altitude
Vibration (B)
OPERATING
0 to 50°
0 to 95% RH
20 g
pk
-500 to 10,000 ft
1.5 g
rms’
0.003 g
2
/Hz
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
pk
-500 to 40,000 ft
5 g
rms’
0.026 g
2
/Hz
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derated output current and toal
output power by 2.5% per °C above 50°C.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com Rev. 02/11/10.
Data Sheet © 2010 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.