Commercial Medical
Model Model
RoHS
Suffix*
Output Output
No.
Output
Minumum
Output
Normal (A)
Forced Air Output Peak
(B)
Noise P-P
OVP
Total Regu-
lation ( C )
GLC110-212 GLM110-212
GLC110-215 GLM110-215
GLC110-524 GLM110-524
G
G
G
1
2
1
2
1
2
1
1
1
+12 V
-12 V
+15 V
-15 V
+24 V
+5 V
1 A
0 A
1 A
0 A
1 A
0 A
0 A
0 A
0 A
6.3 A
2.5 A
5 A
9.1 A
3 A
9.5 A
4 A
100 mV
120 mV
120 mV
150 mV
200 mV
50 mV
15.6 1.1 V
2%
2%
2%
2%
2%
2%
2%
2%
2%
7.3 A
3 A
7.7 A
4 A
18.5 1.5 V
2.5 A
3.2 A
1.5 A
6.3 A
5 A
4.6 A
2 A
4.75 A
2.5 A
9.5 A
7.7 A
5 A
28 2.5 V
6.2 0.6 V
15.6 1.1 V
18.5 1.5 V
28 2.5 V
GLC110-12
GLC110-15
GLC110-24
GLM110-12
GLM110-15
GLM110-24
G
G
G
12 V
9.1 A
7.3 A
4.6 A
120 mV
150 mV
240 mV
15 V
24 V
3.2 A
* Add “G”suffix to part number for RoHS compliant model. Contact factory for availability.
A. Rating with unrestricted convection cooling. Total power not to exceed 75 W; no output can exceed rated current.
B. Rating with 26 cfm forced air cooling. Total power not to exceed 110 W.
C. To maintain regulation V1 current must be at least 1/5 of V2. V1 must not be adjusted more than 1% below nominal and have at least 10% of rated load.
GLC110/GLM110 MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS OPERATING
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 gpk
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derated output current and toal
output power by 2.5% per °C above 50°C.
Temperature (A)
Humidity (A)
Shock (C)
0 to 50°
0 to 95% RH
20 gpk
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
Altitude
-500 to 10,000 ft
-500 to 40,000 ft
C. Shock testing—half-sinusoidal, 10 3 ms duration, direction, 3
orthogonal axes, total 6 shocks.
Vibration (B)
1.5 g rms’0.003 g2/Hz 5 g rms’0.026 g2/Hz
SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com Rev. 02/11/10.
Data Sheet © 2010 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.