GB60S
60W Single Output
General Purpose
General Specifications (continued)
Earth Leakage
<1mA@240Vac, NC
Current
Short Circuit
Protection
Hiccup Mode
Overtemperature
Protection
Not Applicable
Self-recovering
Power Factor
Efficiency
CSA/EN/IEC/UL60950-1, 2nd Edition. See below
for detailed standards information.
88% typical (83% for 12V& 85% for 15V)
60W continuous (55W for 12V models)
Not Applicable
Safety Standards
Isolation
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 500Vac
Output Power
Peak Output
Power
Operating
Temperature
-40C start up. -20C to 80C with derating
specified in Fig.1
Output Power
Derating
See chart above
See Fig.1 on page 4
-40°C to +85°C
Ripple and Noise
Output Voltage
Storage
Temperature
See chart
Voltage
Adjustability
Fixed
5% to 95%, non-condensing
Relative Humidity
Altitude
Operating: 3000 meters
Non-operating: 40,000 ft.
Not required
Minimum Load
+/- 2%. See chart
Over 600,000 hours per Telcordia
Total Regulation
MTBF
Random Vibration per MIL-STD-810E, Method
514.4, Cat. 1, Figure 514.4.1, 1 hour in each of 3
axes.
Transient
Response
500µS max. to 1%, 50% load step. 0.2A/µS,
3.5% deviation typical
Vibration
Shock
Switching
Frequency
Half-sine, 40 gpk, 10 mS duration, +/- in each of
3 axes, 6 shocks total
65kHz, typical
2.0” x 3.0” x 1.0”
50.8 x 76.2 x 25.4mm
126g
Dimensions
Weight
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is .02”.
3. Mounting holes should be connected together for EMI purpose
4. FG is safety ground connection
5. Specifications are for convection rating at factory settings with 115Vac input and 25°C ambient unless otherwise stated.
6. This power supply requires mounting on metal standoffs 0.20” (5mm) in height.
www.slpower.com
GB60S 18-DEC-14
2