40W Single Output
Medical & Industrial Grade
GB40 Family
PROTECTION
SAFETY
Overtemperature
Protection
Will shutdown upon an overtemperature condition,
Auto-recovery
ITE/Industrial Safety
Medical Safety
EN/IEC/UL62368-1
EN/IEC/UL60601-1, 3rd edition
130% to 160% of rated output current value,
Hiccup mode
Overload Protection
Hiccup mode
Short Circuit Protection
Overvoltage Protection
EMI/EMC COMPLIANCE
120% to 150% of nominal output voltage,
Hiccup Mode
EN55032, EN55011/CISPR11 Class B, FCC Part
15.107, Class B: 6db margin type, at 115 and 230VAC
Conducted Emissions
Radiated Emissions
EN55032, EN55011/CISPR11 Class B, FCC Part
15.109, Class B: 3db margin type, at 115 and 230VAC
RELIABILITY
Electro-Static Discharge EN55024/IEC61000-4-2, Level 4: +/- 8kV contact,
>1,000,000 hours, full load, 110 & 220VAC input,
25°C amb., per telcordia 332 issue 6, stress method
MTBF
(ESD) Immunity on
Power Ports
+/- 15kV air, Criteria A
IEC60601-1-2, 4th edition, Table 4
>8 year life based on calculations at 115VAC/60Hz
& 230VAC/50Hz, ambient 25°C at 24 hrs per day,
365 days/year, 6 power up cycles per day
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz,
80% AM at 1kHz
E-cap Life
Radiated RF EM Fields
Susceptibility
IEC60601-1-2, 4th edition, Table 4
EN55024/IEC61000-4-4, Level 4, +/- 4.4kV,
100Khz rep rate, 40A, Criteria A
Electrical Fast
Transients (EFT)/Bursts
ISOLATION SPECIFICATIONS
IEC60601-1-2, 4th edition, Table 5
Input-Output : 4000VAC (2 MOPP)
Input-Ground : 1500VAC (1 MOPP)
Output-Ground : 1500VAC (1 MOPP)
Surges, Line to Line
(Diff Mode) and Line to +/-4kV CM, Criteria A
GND (CMN Mode)
EN55024/IEC61000-4-5, Level 4, +/-2kV DM,
Isolation
Surpasses IEC60601-1-2, 4th edition requirements
EN55022/IEC61000-4-6, 3.6V/m – Level 4, (0.15 to
Conducted Disturbances 80Mhz; and 12V/m) in ISM and amateur radio bands
I/P-O/P, I/P-FG, O/P-FG: TBD
Isolation Resistance
Induced by RF Fields
between 0.15Mhz and 80Mhz, 80% AM at 1KHz
IEC60601-1-2, 4th edition, Table 5
ENVIRONMENT
Rated Power Frequency EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60Hz
Magnetic Fields
IEC60601-1-2, 4th edition, Table 4
-25 ~ +70°C, see derating curve for operation above
60°C
Operating Temperature
EN55024/IECEN61000-4-11:
--100% dip for 10ms, at 0, 45, 90, 135, 180, 225,
270 and 315 degrees, 100% dip for 20ms, 0 deg.,
Criteria A
--100% dip for 5000 ms (250/300 cycles), Criteria B
--60% dip for 100ms, Criteria B
StorageTemperature
Cooling
-40°C ~ +85°C
Convection
Voltage Interruptions,
Dips, Sags & Surges
Relative Humidity
5% to 90%, Non-condensing
--30% dip for 500ms, Criteria A
Operating: 0.003g/Hz, 1.5grms overall, 3 axes,
10 min/axis, 1-500Hz
IEC60601-1-2, 4th edition, Table 5
Non-Oper.: random waveform, 3 minutes per axis, 3
axes and sine waveform, vib. frequency/acceleration:
10-500Hz/1g, sweep rate of 1 octave/minutes,
vibration time of 10 sweeps/axes, 3 axes
Vibration
Shock
Harmonic Current
Emissions
EN55011/EN61000-3-2, Class A
Flicker Test
EN61000-3-3
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks
total
Non-Operating: Half-sine waveform, impact
acceleration of 50G, pulse duration of 6ms,
Number of shocks: 3 for each of the three axis
Note: 1. The power supply is considered a component which will be installed into a final equipment.
The final equipment must be re-confirmed that it still meets EMC directives.
2. All specifications are typical at nominal input, full load, at 25
factory for information regarding testing for or usage under special environments.
°C ambient unless noted. Consult
48.3 x 101.6 x 25mm
2.0 x 4.0 x 0.97 inch (Height is from top of tallest
component to max. component pin protrusion on
the bottom)
Dimensions
Weight
110g
Note: Same dimensions for PCB & Pin Variants.
GB40Datasheet v0420
Copyright © 2020 SL Power Electronics Corp. All rights reserved.
Page 2