Issue Date:
Correction 2
2006-12-04
2008-12-15
Page 1 of 2
Report Reference #
E302267-A10-CB-1
COVER PAGE FOR TEST REPORT
Test Item Description:
Model/Type Reference:
AC-DC Adaptor
JMW140(a)(b)(c)(d)(e)(f), MW153(a)(b)(c)(d)(e)(f).
(a) can be K or C for manufacturing site (K-Bridgepower, C-Wendeng Jeil
Electronics).
(b) can be A to Z for design revision changes.
(c) can be 05, 09, 12, 15, 18, 24 for output voltage.
(d) can be 00 to 99 for the design of output metal connector.
(e) can be F or N for input plug type (F-Class I type, N-Class II type.
(f) can be 00 to 99 for customer options.
See Enclosure-Miscellaneous for the nomenclature of model name in details.
Rating(s):
Rated Input: 100-240 Vac, 50-60Hz, 1.2 A. Rated Output: +5 Vdc/5 A or +9
Vdc/4A or +12 Vdc/3.4A or + 15Vdc/2.7A or +18 Vdc/2.2A or +24 Vdc/1.7A
(Rated output voltage is designated in the model name designation system).
Standards:
IEC 60601-1:1988 + A1:1991 + A2:1995
Applicant Name and
Address:
BRIDGEPOWER CORP
964 GOSAEK-DONG
GWONSEON-GU
SUWON-SI GYEONGGI-DO 441-813 KOREA
Factory Location(s):
BRIDGEPOWER CORP
964 GOSAEK-DONG
GWONSEON-GU
SUWON-SI GYEONGGI-DO 441-813 KOREA
WENDENG JEIL ELECTRONICS CO LTD
DONG SHOU GUANGZHOU LU
KAIFA-QU
WENDENG-SHI SHANDONG CHINA
This Report includes the following parts, in addition to this cover page:
1. Specific Technical Criteria
2. Clause Verdicts
3. Critical Components
The original report was modified on 2008-12-15 to include the following changes/additions:
Project No. 08CA63174 (E302267-A10-CB-1, Amendment 1, Correction1, Correction2)
1. Company name change from "JEC KOREA CORP" to "BRIDGEPOWER CORP"
2. Company address change, See Report cover page for new address.
3. Delete factory "AULT KOREA CORPORATION"
4. Revised typo error.
All applicable tests according to the above standard(s) have been carried out.
Test results are valid only for the tested equipment.
This Test Report can be reproduced only in whole.
Amendments and corrections can be reproduced only with the original CB Test Report.
Written permission from UL International Demko A/S is required if the test report is copied in part.
UL International Demko A/S