欢迎访问ic37.com |
会员登录 免费注册
发布采购

CINT1200 参数 Datasheet PDF下载

CINT1200图片预览
型号: CINT1200
PDF下载: 下载PDF文件 查看货源
内容描述: [200W Single Output Industrial Series]
分类和应用:
文件页数/大小: 3 页 / 495 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号CINT1200的Datasheet PDF文件第1页浏览型号CINT1200的Datasheet PDF文件第3页  
CINT1200  
200W Single Output  
Industrial Series  
Specifications (continued)  
Sensing transformer temperature, 165°C at  
full load, latching type, requires input power  
recycling to reset.  
Overtemperature  
Protection  
264Vac, cold start: will not exceed 55A  
Inrush Current  
F1, F2: 3.15A, 250Vac fuses provided on all  
models  
120 to 150% of rating, Hiccup Mode  
Hiccup Mode, auto recovery.  
Input Fuses  
Overload Protection  
Earth Leakage  
Current  
Short Circuit  
Protection  
<500µA@264Vac, 60Hz, NC; <1mA SFC  
Overvoltage  
Protection  
88% typical  
OVP latch, see models chart for trip range.  
Efficiency  
200W continuous, with 100 lfm airflow, 180W  
convection cooled – See chart for specific  
voltage model ratings.  
PFC: Fixed, 65kHz  
Main Converter: Variable 35-200kHz, 65-  
70kHz at full load.  
Output Power  
Switching Frequency  
Isolation  
500µS typical, return to 0.5% of nominal, 50%  
load step. i/t: <0.2A/µS. Max Voltage  
Deviation = 3%  
Input-Output: 4000Vac  
Input-Ground: 1800Vac  
Output-Ground: 1500Vac  
Transient  
Response  
Operating  
Temperature  
-10°C to +70°C  
Start Up at -40°C, full load  
0.5%rms, 1% pk-pk, see chart.  
See chart  
Ripple and Noise  
Output Voltage  
Temperature  
Derating  
Derate output power linearly above 50°C to  
50% at 70°C  
Voltage  
Adjustability  
Fixed Output  
-40°C to +85°C  
Storage Temperature  
Altitude  
Operating: -500 to 10,000 ft.  
Non-operating: -500 to 40,000 ft.  
Not required  
Minimum Load  
+/- 3% combined line, load and initial setting.  
5% to 95%, non-condensing  
Total Regulation  
Relative Humidity  
Operating: 0.003g²/Hz, 1.5grms overall, 3  
axes, 10 min/axis  
Non-Operating: 0.026g²/Hz, 5.0grms overall,  
3 axes, 1 hr/axis  
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6  
shocks total  
Non-Operating: Half-sine, 40 gpk, 10 ms, 3  
axes, 6 shocks total  
Vibration  
Shock  
W: 3.0” x L: 5.0” x H: 1.3”  
EN/CSA/UL/IEC 60950-1, 2nd Edition  
Dimensions  
Weight  
Safety Standards  
MTBF  
325g  
401,000 hours, 25°C, 110Vac  
Output vs. Temperature Derating Curve  
180W convection cooled and 200W continuous with 100 LFM airflow, derate output power to 50% at 70°C.  
www.slpower.com  
CINT1200 REV 1.4 12-JUNE-13  
2