欢迎访问ic37.com |
会员登录 免费注册
发布采购

CINT1200A2475K01 参数 Datasheet PDF下载

CINT1200A2475K01图片预览
型号: CINT1200A2475K01
PDF下载: 下载PDF文件 查看货源
内容描述: [AC-DC Regulated Power Supply Module, 200W]
分类和应用: 输出元件
文件页数/大小: 3 页 / 496 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号CINT1200A2475K01的Datasheet PDF文件第1页浏览型号CINT1200A2475K01的Datasheet PDF文件第2页  
CINT1200
200W Single Output
Industrial Series
EMI/EMC Compliance
Conducted Emissions
Radiated Emissions
Static Discharge Immunity
Radiated RF Immunity
EFT/Burst Immunity
Line Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field Immunity
Voltage Dip Immunity
Line Harmonic Emissions
Flicker Test
EN55011/22 Class B, FCC Part 15, Subpart B, Class B
EN55011/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
EN61000-4-3, 3V/m.
EN61000-4-4, 2kV/5kHz
EN61000-4-5, 1kV differential, 2kV common-mode
EN61000-4-6, 3Vrms
EN61000-4-8, 3A/m
EN61000-4-11, 100%, 10ms; 30%, 275ms; 60%, 100ms; Performance
Criteria A, A, & A at 70% load.
EN61000-3-2, Class A, B, C, & D
EN61000-3-3, Complies (dmax<6%)
Mechanical Drawing
Notes:
1. All dimensions in inches (mm), tolerance
is +/-0.000”.
2. Mounting holes should be grounded for
EMI purposes.
3. FG is safety ground connection.
4. The power supply requires mounting on
metal standoffs 0.20” (5mm) in height, min.
[4] x 0.156
4 PLCS
MTG
HOLES
Connector Information
Input Connector
J100
PIN 1) AC LINE
PIN 2) EMPTY
PIN 3) AC NEUTRAL
Mating Connector:
AMP Molex 640250-3
Pins: 640252-2
Ground
(FG)
0.25” FASTON TAB
DC Output Connector
J300
Term. 1,2,3: RTN
Term. 4,5,6: +Vout
Mating Connector:
AMP 640250-6
Pins: 640252-2
Mating Connector:
Molex 190020001
Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
CINT1200 REV 1.4 12-JUNE-13