欢迎访问ic37.com |
会员登录 免费注册
发布采购

CINT1200A1275K01 参数 Datasheet PDF下载

CINT1200A1275K01图片预览
型号: CINT1200A1275K01
PDF下载: 下载PDF文件 查看货源
内容描述: [AC-DC Regulated Power Supply Module, 200W]
分类和应用: 输出元件
文件页数/大小: 3 页 / 496 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号CINT1200A1275K01的Datasheet PDF文件第1页浏览型号CINT1200A1275K01的Datasheet PDF文件第3页  
CINT1200
200W Single Output
Industrial Series
Specifications
(continued)
Inrush Current
264Vac, cold start: will not exceed 55A
Overtemperature
Protection
Overload Protection
Short Circuit
Protection
Overvoltage
Protection
Switching Frequency
Sensing transformer temperature, 165° at
C
full load, latching type, requires input power
recycling to reset.
120 to 150% of rating, Hiccup Mode
Input Fuses
Earth Leakage
Current
Efficiency
F1, F2: 3.15A, 250Vac fuses provided on all
models
<500µA@264Vac, 60Hz, NC; <1mA SFC
Hiccup Mode, auto recovery.
88% typical
200W continuous, with 100 lfm airflow, 180W
convection cooled – See chart for specific
voltage model ratings.
500µS typical, return to 0.5% of nominal, 50%
load step.
∆i/∆t:
<0.2A/µS. Max Voltage
Deviation = 3%
0.5%rms, 1% pk-pk, see chart.
OVP latch, see models chart for trip range.
PFC: Fixed, 65kHz
Main Converter: Variable 35-200kHz, 65-
70kHz at full load.
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 1500Vac
-10° to +70°
C
C
Start Up at -40° full load
C,
Derate output power linearly above 50° to
C
50% at 70°
C
Output Power
Transient
Response
Ripple and Noise
Isolation
Operating
Temperature
Temperature
Derating
Storage Temperature
Output Voltage
Voltage
Adjustability
Minimum Load
See chart
Fixed Output
-40° to +85°
C
C
Not required
Altitude
Operating: -500 to 10,000 ft.
Non-operating: -500 to 40,000 ft.
Total Regulation
+/- 3% combined line, load and initial setting.
Operating: 0.003g²/Hz, 1.5grms overall, 3
axes, 10 min/axis
Non-Operating: 0.026g²/Hz, 5.0grms overall,
3 axes, 1 hr/axis
W: 3.0” x L: 5.0” x H: 1.3”
Relative Humidity
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3
axes, 6 shocks total
EN/CSA/UL/IEC 60950-1, 2nd Edition
Vibration
Shock
Dimensions
Safety Standards
Weight
325g
MTBF
401,000 hours, 25°C, 110Vac
Output vs. Temperature Derating Curve
180W convection cooled and 200W continuous with 100 LFM airflow, derate output power to 50% at 70°C.
www.slpower.com
CINT1200 REV 1.4 12-JUNE-13
2