CINT1175
175W Single Output
Industrial Series
Output Specifications (continued)
Parameter
Conditions/Description
Min
Nom
Max
Units
Hold-Up Time
Starting at Vi = 230 VAC, Po nom
-
16
-
ms
Load change =50%, di/dt =0.2A/μS
Dynamic Load Regulation
Start-Up Time
0
0
3
2
% Vo nom
voltage deviation 3%
Vi nom, Io nom
-
s
Protection
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted
Parameter
Input Fuse
Conditions/Description
Not user accessible
Min
Nom
Max
Units
Input Transient Protection
2KV(CM) and 1KV(DM) surge
2
KV (CM)
No-load and short circuit proof
short circuit proof
Hiccup or Latch
Hiccup or Latch
Hiccup
Output
overload (latch style)
Latch style
Overvoltage Protection
Latch
Over temperature Protection
Automatic power shutdown at TC =155°C
Characteristic Curves
Output vs. Temperature
120W convection cooled and 175W continuous with 200 LFM airflow, Derating output power to 50% at 70C.