CINT1150
150W Single Output
Industrial Series
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Min
Nom
Max
Units
Input Voltage
Turn-On Input Voltage
Turn-Off Input Voltage
Input Frequency
90
115/230
82.7
67.0
50/60
-
264
Vac
Vac
Vac
Hz
Ramping up
Ramping down
47
-
63
50
-
Inrush Current Limitation
Power Factor
264Vac, cold start
A
Vi nom, Io nom
0.9
-
Vi nom, Io nom
CINT1150A1206K01
CINT1150A2406K01
CINT1150A4806K01
CINT1150A5606K01
Efficiency
88%
-
%
-
Protection
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted
Parameter
Input Fuse
Conditions/Description
Not user accessible
Min
Nom
Max
Units
Input Transient Protection
2KV(CM) and 1KV(DM) surge
2
KV (CM)
No-load
Short Circuit
Overload
Hiccup Mode
Hiccup Mode
Hiccup Mode
Output
Overvoltage Protection
Latch style
See Models chart for trip ranges
Over temperature Protection
Automatic power shutdown at TC =155°C
Characteristic Curves
Output vs. Temperature
100W convection cooled and 150W continuous with 200 LFM airflow, Derating output power to 50% at 70C.
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
5