欢迎访问ic37.com |
会员登录 免费注册
发布采购

CINT1150A2406K01 参数 Datasheet PDF下载

CINT1150A2406K01图片预览
型号: CINT1150A2406K01
PDF下载: 下载PDF文件 查看货源
内容描述: 该CINT1150系列是最新推出的高密度单输出开架式AC / DC电源。 [The CINT1150 family is the latest offering in high density single output open-frame AC/DC power supplies.]
分类和应用:
文件页数/大小: 8 页 / 636 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号CINT1150A2406K01的Datasheet PDF文件第1页浏览型号CINT1150A2406K01的Datasheet PDF文件第3页浏览型号CINT1150A2406K01的Datasheet PDF文件第4页浏览型号CINT1150A2406K01的Datasheet PDF文件第5页浏览型号CINT1150A2406K01的Datasheet PDF文件第6页浏览型号CINT1150A2406K01的Datasheet PDF文件第7页浏览型号CINT1150A2406K01的Datasheet PDF文件第8页  
CINT1150  
150W Single Output  
Industrial Series  
General Specifications (continued)  
Earth Leakage  
<750μA@264Vac, 60Hz, NC  
Current  
Short Circuit  
Protection  
Provided - no damage will occur if the output  
is shorted. Hiccup Mode  
OVP firing reduces output voltage to <50%  
of nominal in <50mS. See chart for trip  
range.  
Overvoltage  
Protection  
88% typical at 115Vac  
Efficiency  
150W continuous with 200 lfm airflow, 100W  
convection cooled – See chart for specific  
voltage model ratings.  
PFC: Variable 30-400kHz.  
Main Converter: Variable 35-180kHz, 65-  
70kHz at full load.  
Output Power  
Switching Frequency  
Isolation  
Input-Output: 4000Vac  
Input-Ground: 1800Vac  
Output-Ground: 500Vac  
Transient  
Response  
50% load step. i/t: <0.2A/μS  
Max Volt Deviation = 3%  
Operating  
Temperature  
See chart  
-10°C to +70°C  
Ripple and Noise  
Output Voltage  
Temperature  
Derating  
Derate output power linearly above 50°C to  
50% at 70°C  
See chart  
Voltage  
Adjustability  
+/-5% from nominal  
Not required  
-40°C to +85°C  
Storage Temperature  
Altitude  
Operating: -500 to 10,000 ft  
Non-operating: -500 to 40,000 ft.  
Minimum Load  
+/- 5%. See chart  
5% to 95%, non-condensing  
Total Regulation  
Relative Humidity  
Operating: 0.003g/Hz, 1.5grms overall, 3  
axes, 10 min/axis  
Non-Operating: 0.026g2/Hz, 5.0grms overall,  
3 axes, 1 hr/axis  
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6  
shocks total  
Non-Operating: Half-sine, 40 gpk, 10 ms, 3  
axes, 6 shocks total  
Vibration  
Shock  
W: 2.0” x L: 4.0” x H: 1.3”  
183g  
EN/CSA/UL/IEC60950-1, 2nd Edition  
Dimensions  
Weight  
Safety Standards  
MTBF  
640,000 hours at 100W convection,  
1,500,000 hours at 150W with 200LFM air  
Auxiliary Signals  
Goes LOW with 5 mS warning before loss  
of output power due to AC failure  
During normal operations, stays HIGH.  
AC Power Fail:  
Power Fail:  
DC OK:  
Open collector logic signal goes and stays HIGH  
100mS to 500mS after main output reaches  
regulation.  
www.slpower.com  
CINT1150 REV 2.6, 12-NOV-12  
2