CINT1150
150W Single Output
Industrial Series
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Input Voltage
Turn-On Input Voltage
Turn-Off Input Voltage
Input Frequency
Inrush Current Limitation
Power Factor
Conditions/Description
Ramping up
Ramping down
Min
90
Nom
115/230
82.7
67.0
Max
264
Units
Vac
Vac
Vac
47
264Vac, cold start
Vi
nom,
Io
nom
Vi
nom,
Io
nom
CINT1150A1206K01
CINT1150A2406K01
CINT1150A4806K01
CINT1150A5606K01
-
0.9
50/60
-
-
63
50
-
Hz
A
Efficiency
-
88%
-
%
Protection
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted
Parameter
Input Fuse
Input Transient Protection
Conditions/Description
Not user accessible
2KV(CM) and 1KV(DM) surge
No-load
Min
Nom
Max
2
Hiccup Mode
Hiccup Mode
Hiccup Mode
Units
KV (CM)
Output
Short Circuit
Overload
Latch style
Automatic power shutdown at TC =155°C
Overvoltage Protection
Over temperature Protection
See Models chart for trip ranges
Characteristic Curves
Output vs. Temperature
100W convection cooled and 150W continuous with 200 LFM airflow, Derating output power to 50% at 70C.
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
5