DATA SHEET • AS219-321, AS219-321LF
Operating Characteristics at 25 °C (0, 3 V)
Parameter
Condition
Frequency
Min.
Typ.
Max.
Unit
Switching characteristics
Rise, fall
On, off
10/90% or 90/10% RF
50% CTL to 90/10% RF
60
100
50
ns
ns
mV
Video feedthru
T
RISE
= 1 ns, BW = 500 MHz
Input power for -0.1 dB compression
0/3 V
0.9 GHz
35
-70
25
dBm
dBc
Harmonics H , H (transmit state)
P
IN
= 34.5 dBm
0.9 GHz, 1.8 GHz
2
3
Thermal resistance
Control voltages
°C/W
V
LOW
V
HIGH
= 0 to 0.2 V @ 20 µA max.
= 2.7 V @ 100 µA max. to 5 V @ 200 µA max.
Typical Performance Data
0
-0.2
-0.4
-10
-15
-20
-25
-30
-35
-40
-45
-50
Ant-Tx
-0.6
-0.8
-1.0
-1.2
-1.4
-1.6
-1.8
-2.0
Ant-Rx1
Ant-Tx
Ant-Rx1
Ant-Rx2
Ant-Rx2
0
0.5
1.0
1.5
2.0
2.5
0
0.5
1.0
1.5
2.0
2.5
Frequency (GHz)
Frequency (GHz)
Isolation vs. Frequency
Insertion Loss vs. Frequency
0
-60
-65
-70
-75
-80
-85
-90
-95
-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
Ant-Rx1
3rd Harmonic
Ant-Rx2
Ant-Tx
2nd Harmonic
0
0.5
1.0
1.5
2.0
2.5
2.6
3.0
3.4
3.8
4.2
4.6
5.0
Frequency (GHz)
Control Voltages (V)
Return Loss vs. Frequency
0.9 GHz Harmonics vs. Control Voltages
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
May 30, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200250 Rev. B
2