ST7669V
9.1.6 RDDMADCTL: Read Display MADCTL (0BH)
A0
0
RD
1
WR
0
D7
0
D6
0
D5
0
D4
0
D3
1
D2
0
D1
1
D0
1
HEX
Command
1st parameter
2nd parameter
0BH
1
0
1
-
-
-
-
-
-
-
-
-
-
1
0
1
D7
D6
D5
D4
D3
0
0
0
NOTE: “-“ Don’t care
Description
This command indicates the current status of the display as described in the table below:
Bit
D7
D6
D5
Description
Value
Row Address Order (MY)
Column Address Order (MX)
Row/Column Order (MV)
“1”=Decrement, “0”=Increment
“1”=Decrement, “0”=Increment
“1”= Row/column exchange (MV=1)
“0”= Normal (MV=0)
D4
D3
D2
D1
D0
Scan Address Order (ML)
RGB/BGR Order (RGB)
Not Used
“1”=Decrement, “0”=Increment
“1”=BGR, “0”=RGB
“0”
“0”
“0”
Not Used
Not Used
Restriction
Register
Availability
Status
Availability
Normal Mode On, Idle Mode Off, Sleep Out
Normal Mode On, Idle Mode On, Sleep Out
Partial Mode On, Idle Mode Off, Sleep Out
Partial Mode On, Idle Mode On, Sleep Out
Sleep In
Yes
Yes
Yes
Yes
Yes
Default
Status
Power On Sequence
S/W Reset
Default Value (D7 to D0)
0000_0000 (00h)
No change
H/W Reset
0000_0000 (00h)
Ver 1.3
76/208
6/4/2008