ST7628
9.1.68 FRMSEL: Frame Freq. in Temp. range (F0H)
A0
0
RD
1
WR
0
D7
D6
D5
D4
1
D3
0
D2
0
D1
0
D0
0
HEX
Command
1st parameter
2nd parameter
3rd parameter
4th parameter
1
-
1
-
1
-
F0H
1
1
0
FA4
FB4
FA3
FB3
FA2
FA1
FA0
FB0
Range A
Range B
Range C
Range D
1
1
0
-
-
-
FB2 FB1
1
1
0
-
-
-
FC4 FC3 FC2 FC1 FC0
FD4 FD3 FD2 FD1 FD0
1
1
0
-
-
-
Description
Select Frame Freq. in normal display mode.
1st parameter : Frame freq. value set in temperature range 30(-30℃) to TA
2nd parameter : Frame freq. value set in temperature P range TA to TB
3rd parameter : Frame freq. value set in temperature range TB to TC
4th parameter : Frame freq. value set in temperature range TC to 145(90℃)
For command setting to frame rate value look-up-table, please see the following table:
Frame Rate
Reg(dec)
Reg(hex)
(Hz)
37.5
38
0
1
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
2
38.5
40
3
4
42
5
44
6
46
7
48.5
51
8
9
54
10
11
12
13
14
15
16
17
18
19
20
57.5
61.5
66.5
72
77.5
85
75
76
77
80
84