BTB41
Discrete Triacs(Non-Isolated)
STATIC CHARACTERISTICS
Symbol
Test Conditions
Tj = 25°C
Value
Unit
I
= 60 A
tp = 380 µs
MAX.
1.55
V
V
V
(2)
(2)
TM
TM
V
Threshold voltage
Tj = 125°C
Tj = 125°C
Tj = 25°C
Tj = 125°C
0.85
10
5
MAX.
MAX.
to
R (2)
Dynamic resistance
mΩ
d
I
I
V
= V
RRM
µA
DRM
RRM
DRM
MAX.
5
mA
Note 1: minimum IGT is guaranted at 5% of IGT max.
Note 2: for both polarities of A2 referenced to A1
THERMAL RESISTANCES
Symbol
Parameter
Value
Unit
R
Junction to case (AC)
Junction to ambient
°C/W
0.6
50
th(j-c)
R
°C/W
th(j-a)
PRODUCT SELECTOR
Part Number
Voltage (xxx)
Sensitivity
Type
Package
~~
200 V
1000 V
BTB41
X
X
50 mA
Standard
TO-247AD
OTHER INFORMATION
Base
quantity
Packing
mode
Part Number
Marking
Weight
BTB41
120
Bulk
6 g
BTB41
P2
©2008 SIRECTIFIER All rights reserved,
Tel: +86-519-86800000 Fax: +86-519-88019019 E-mail: sales@sirectifier.com
www.sirectifier.com