With the Air Discharge Method, an ESD voltage  
is applied to the equipment under test (EUT)  
throughair. Thissimulatesanelectricallycharged  
person ready to connect a cable onto the rear of  
the system only to find an unpleasant zap just  
before the person touches the back panel. The  
high energy potential on the person discharges  
through an arcing path to the rear panel of the  
system before he or she even touches the system.  
This energy, whether discharged directly or  
through air, is predominantly a function of the  
discharge current rather than the discharge  
voltage. Variables with an air discharge such as  
approach speed of the object carrying the ESD  
potential to the system and humidity will tend to  
change the discharge current. For example, the  
rise time of the discharge current varies with the  
approach speed.  
30A  
15A  
0A  
t=0ns  
t=30ns  
t  
Figure 9. ESD Test Waveform for IEC1000-4-2  
voltage stored in the capacitor is then applied  
throughRS, thecurrentlimitingresistor, ontothe  
device under test (DUT). In ESD tests, the SW2  
switch is pulsed so that the device under test  
receives a duration of voltage.  
The Contact Discharge Method applies the ESD  
current directly to the EUT. This method was  
devised to reduce the unpredictability of the  
ESD arc. The discharge current rise time is  
constant since the energy is directly transferred  
without the air-gap arc. In situations such as  
handheldsystems,theESDchargecanbedirectly  
dischargedtotheequipmentfromapersonalready  
holdingtheequipment. Thecurrentistransferred  
ontothekeypadortheserialportoftheequipment  
directly andthentravelsthroughthePCBandfinally  
to the IC.  
FortheHumanBodyModel, thecurrentlimiting  
resistor (R ) and the source capacitor (C ) are  
1.5kan 1S00pF, respectively. For IEC-10S00-4-  
2,thecurrentlimitingresistor(RS)andthesource  
capacitor (CS) are 330an 150pF, respectively.  
The higher C value and lower RS value in the  
IEC1000-4-2Smodel are more stringent than the  
HumanBodyModel. Thelargerstoragecapacitor  
injects a higher voltage to the test point when  
SW2 is switched on. The lower current limiting  
resistor increases the current charge onto the test  
point.  
The circuit model in Figures 7 and 8 represent  
the typical ESD testing circuit used for all three  
methods. TheCS isinitiallychargedwiththeDC  
power supply when the first switch (SW1) is on.  
Now that the capacitor is charged, the second  
switch(SW2)isonwhileSW1switchesoff. The  
SP481E, SP485E  
FAMILY  
HUMAN BODY  
MODEL  
IEC1000-4-2  
Air Discharge Direct Contact  
Level  
Driver Outputs  
Receiver Inputs  
±15kV  
±15kV  
±15kV  
±15kV  
±8kV  
±8kV  
4
4
Rev. 5/16/03  
SP481E Low Power Half-Duplex RS485 Transceivers  
© Copyright 2003 Sipex Corporation  
8