SA276
While the magnetic flux density B is larger than operate point Bop, DO will turn on and output low potential,
DOB will turn off and output high potential. Each output is latched until the magnetic flux density B is lower than
release point Brp, and then DO; DOB transfer each state.
PIN CONFIGURATION
SA276
1
2
3
4
PIN DESCRIPTION
Pin No.
Symbol
Description
1
VCC
DO
Power supply
Positive output
2
3
4
DOB
GND
Negative output
Ground.
HALL SENSOR LOCATION
Unit
mm
mm
X
Y
1.75
1.35
TEST CIRCUIT
HANGZHOU SILAN MICROELECTRONICS CO.,LTD
Http: www.silan.com.cn
REV: 1.2
2008.09.27