Si3056  
Si3018/19/10  
passes through the internal filters and transmitted on When the HBE bit is cleared, this causes a dc offset that  
SDO which introduces approximately 0.9 dB of affects the signal swing of the transmit signal. Silicon  
®
attenuation on the SDI signal received. The group delay Laboratories recommends that the transmit signal be  
of both transmit and receive filters exists between SDI 12 dB lower than normal transmit levels. A lower level  
and SDO. Clearing the PDL bit disables this mode and eliminates clipping from the dc offset that results from  
the SDO data is switched to the receive data from the disabling the hybrid. It is assumed in this test that the  
line-side. When the PDL bit is cleared, the FDT bit line ac impedance is nominally 600 Ω.  
(Register 12, bit 6) becomes active, indicating the  
successful communication between the line-side and  
DSP-side. This can be used to verify that the isolation  
link is operational.  
The digital data loop-back mode offers a way to input  
data on the SDI pin and have the identical data be  
output on the SDO pin by bypassing the transmit and  
receive filters. Setting the DDL bit (Register 10, bit 0)  
enables this mode. No line-side power or off-hook  
Note: All test modes are mutually exclusive. If more than one  
test mode is enabled concurrently, the results are  
unpredictable.  
5.31. Exception Handling  
The Si3056 provides several mechanisms to determine  
if an error occurs during operation. Through the  
secondary frames of the serial link, the controlling  
systems can read several status bits.  
sequence is required for this mode. The digital data The bit of highest importance is the frame detect bit  
loopback mode is useful to verify communication (FDT, Register 12, bit 6), which indicates that the  
between the host processor/DSP and the DAA.  
system-side (Si3056) and line-side devices are  
communicating.  
The remaining test modes require an off-hook sequence  
to operate. The following sequence describes the off- During normal operation, the FDT bit can be checked  
hook procedure required for the following test modes:  
1. Powerup or reset.  
before reading bits for information about the line-side. If  
FDT is not set, the following bits related to the line-side  
are invalid—RDT, RDTN, RDTP, LCS[4:0], LSID[1:0],  
REVB[3:0], LCS2[7:0], LVS[7:0], ROV, BTD, DOD, and  
OVL; the RGDT operation is also non-functional.  
2. Program the clock generator to the chosen sample  
rate.  
3. Enable line-side by clearing the PDL bit.  
4. Issue an off-hook command.  
5. Delay 402.75 ms to allow calibration to occur.  
6. Set the desired test mode.  
In the communications link loopback mode, the host  
sends a digital input test pattern on SDI and receives  
that digital test pattern back on SDO. To enable this  
mode, set the IDL bit (Register 1, bit 1). In this mode,  
the communication link is tested. The digital stream is  
delivered across the isolation capacitors, C1 and C2 of  
Figure 16 on page 17, to the line-side device and  
returned across the same interface. In this mode, the  
0.9 dB attenuation and filter group delays also exist.  
Following Powerup and reset, the FDT bit is not set  
because the PDL bit (Register 6 bit 4) defaults to 1. The  
communications link does not operate and no  
information about the line-side can be determined. The  
user must program the clock generator to a valid  
configuration for the system and clear the PDL bit to  
activate the communications link. As the system- and  
line-side devices are establishing communication, the  
system-side device does not generate FSYNC signals.  
Establishing communication takes less than 10 ms.  
Therefore, if the controlling DSP serial interface is  
interrupt driven based on the FSYNC signal, the  
controlling DSP does not require a special delay loop to  
wait for this event to complete.  
The final testing mode, internal analog loopback, allows  
the system to test the operation of the transmit and  
receive paths through the line-side device and the  
external components shown in Figure 16 on page 17. In  
this test mode, the host provides a digital test waveform  
on SDI. This data passes across the communications  
link, is transmitted to and received from the line, passes  
back across the communications link, and is presented  
to the host on SDO. To enable this mode, clear the HBE  
bit (Register 2, bit 1).  
The FDT bit also can indicate if the line-side device  
executes an off-hook request successfully. If the line-  
side device is not connected to a phone line, the FDT bit  
remains cleared. The controlling DSP must provide  
sufficient time for the line-side to execute the off-hook  
request. The maximum time for FDT to be valid  
following an off-hook request is 10 ms. If the FDT bit is  
high, the LCS[4:0] bits indicate the amount of loop  
current flowing. If the FDT fails to be set following an off-  
hook request, the PDL bit (Register 6) must be set high  
for at least 1 ms to reset the line-side.  
40  
Rev. 1.05  