Si3056  
Si3018/19/10  
SRC[3:0] bits (Register 7, bits 3:0) must be The Si3056 also supports an additional powerdown  
programmed with the proper sample rate value before mode. When both the PDN (Register 6, bit 3) and PDL  
the sampled line data is valid. The SCLK pin of the (Register 6, bit 4) bits are set, the chipset enters a  
slave is a no connect in this configuration.  
complete powerdown mode and draws negligible  
current (deep sleep mode). Turn off the PLL2 before  
entering deep sleep mode (i.e., set Register 9 to 0 and  
then Register 6 to 0x18). In this mode, the Si3056 is  
non-functional. Normal operation is restored by the  
same process for taking the DAA out of sleep mode.  
The delay between FSYNC input and delayed frame  
sync output (RGDT/FSD/M1) is 16 SCLK periods. The  
RGDT/FSD/M1 output has a waveform identical to the  
FSYNC signal in serial mode 0. In addition, the LSB of  
SDO is set to 0 by default for all devices in serial  
mode 2.  
5.29. Calibration  
5.28. Power Management  
The Si3056 initiates two auto-calibrations by default  
when the device goes off-hook or experiences a loss in  
line power. A 17 ms resistor calibration is performed to  
allow circuitry internal to the DAA to adjust to the exact  
line conditions present at that time. This resistor  
calibration can be disabled by setting the RCALD bit  
(Register 25, bit 5). A 256 ms ADC calibration is also  
performed to remove offsets that might be present in the  
on-chip A/D converter which could affect the A/D  
dynamic range. The ADC auto-calibration is initiated  
after the DAA dc termination stabilizes, and the resistor  
calibration completes. Because large variations in line  
conditions and line card behavior exist, it could be  
beneficial to use manual calibration instead of auto-  
calibration.  
The Si3056 supports four basic power management  
operation modes. The modes are normal operation,  
reset operation, sleep mode, and full powerdown mode.  
PDN and PDL bits (Register 6) control the power  
management modes.  
On powerup, or following a reset, the Si3056 is in reset  
operation. The PDL bit is set, and the PDN bit is  
cleared. The Si3056 is operational, except for the  
isolation link. No communication between the Si3056  
and line-side device can occur during reset operation.  
Bits associated with the line-side device are not valid in  
this mode.  
In typical applications, the DAA will predominantly be  
operated in normal mode. In this mode, the PDL and  
PDN bits are cleared. The Si3056 is operational and the  
isolation link is passing information between the Si3056  
and the line-side device.  
Execute manual ADC calibration as close as possible to  
256 ms before valid transmit/receive data is expected.  
Take the following steps to implement manual ADC  
calibration:  
The Si3056 supports a low-power sleep mode to  
support ring validation and wake-on-ring features. The  
clock generator registers 7, 8, and 9 must be  
1. The CALD (auto-calibration disable—Register 17) bit  
must be set to 1.  
programmed with valid, non-zero values and the PDL 2. The MCAL (manual calibration) bit must be toggled  
bit must be clear before enabling sleep mode. The PDN  
bit must then be set. When the Si3056 is in sleep mode  
the MCLK signal must remain active. In low-power  
sleep mode with MCLK active, the Si3056 is non-  
functional except for the isolation link and the RGDT  
signal. To take the Si3056 out of sleep mode, pulse the  
reset pin (RESET) low.  
to 1 and then 0 to begin and complete the  
calibration.  
3. The calibration is completed in 256 ms.  
5.30. In-Circuit Testing  
With the Si3056’s advanced design the designer can  
determine system functionality during production line  
In summary, the powerdown/up sequence for sleep tests, and during support for end-user diagnostics. Four  
mode is as follows:  
loopback modes allow thorough coverage of system  
components. Four of the test modes require a line-side  
power source. Although a standard phone line can be  
used, the test circuit in Figure 1 on page 6 is adequate.  
In addition, an off-hook sequence must be performed to  
connect the power source to the line-side device.  
For the start-up loopback test mode, line-side power is  
not necessary and no off-hook sequence is required.  
The start-up test mode is enabled by default. When the  
PDL bit (Register 6, bit 4) is set (the default case), the  
line-side is in a powerdown mode and the DSP-side is  
in a digital loop-back mode. Data received on SDI  
1. Ensure that Registers 7, 8, and 9 have valid non-  
zero values, and ensure the PDL bit (Register 6, bit  
4) is cleared.  
2. Set the PDN bit (Register 6, bit 3).  
3. The device is now in sleep mode. MCLK must stay  
active.  
4. To exit sleep mode, reset the Si3056 by pulsing the  
RESET pin.  
5. Program registers to desired settings.  
Rev. 1.05  
39  