Si1000/1/2/3/4/5
Recommended Instruction Timing for a single register write with short strobe enabled:
mov RTC0ADR, #095h
mov RTC0DAT, #000h
nop
20.1.4. SmaRTClock Interface Autoread Feature
When Autoread is enabled, each read from RTC0DAT initiates the next indirect read operation on the
SmaRTClock internal register selected by RTC0ADR. Software should set the BUSY bit once at the begin-
ning of each series of consecutive reads. Software should follow recommended instruction timing or check
if the SmaRTClock Interface is busy prior to reading RTC0DAT. Autoread is enabled by setting AUTORD
(RTC0ADR.6) to logic 1.
20.1.5. RTC0ADR Autoincrement Feature
For ease of reading and writing the 32-bit CAPTURE and ALARM values, RTC0ADR automatically incre-
ments after each read or write to a CAPTUREn or ALARMn register. This speeds up the process of setting
an alarm or reading the current SmaRTClock timer value. Autoincrement is always enabled.
Recommended Instruction Timing for a multi-byte register read with short strobe and autoread enabled:
mov RTC0ADR, #0d0h
nop
nop
nop
mov A, RTC0DAT
nop
nop
mov A, RTC0DAT
nop
nop
mov A, RTC0DAT
nop
nop
mov A, RTC0DAT
Recommended Instruction Timing for a multi-byte register write with short strobe enabled:
mov RTC0ADR, #010h
mov RTC0DAT, #05h
nop
mov RTC0DAT, #06h
nop
mov RTC0DAT, #07h
nop
mov RTC0DAT, #08h
nop
Rev. 1.0
193