13.6. Minimizing Flash Read Current
The Flash memory in the Si1000/1/2/3/4/5 devices is responsible for a substantial portion of the total digital
supply current when the device is executing code. Below are suggestions to minimize Flash read current.
1. Use Idle, Suspend, or Sleep Modes while waiting for an interrupt, rather than polling the interrupt flag.
Idle Mode is particularly well-suited for use in implementing short pauses, since the wake-up time is no
more than three system clock cycles. See the Power Management chapter for details on the various
low-power operating modes.
2. Si1000/1/2/3/4/5 devices have a one-shot timer that saves power when operating at system clock
frequencies of 10 MHz or less. The one-shot timer generates a minimum-duration enable signal for the
Flash sense amps on each clock cycle in which the Flash memory is accessed. This allows the Flash to
remain in a low power state for the remainder of the long clock cycle.
At clock frequencies above 10 MHz, the system clock cycle becomes short enough that the one-shot
timer no longer provides a power benefit. Disabling the one-shot timer at higher frequencies reduces
power consumption. The one-shot is enabled by default, and it can be disabled (bypassed) by setting
the BYPASS bit (FLSCL.6) to logic 1. To re-enable the one-shot, clear the BYPASS bit to logic 0. See
the note in SFR Definition 13.3. FLSCL: Flash Scale for more information on how to properly clear the
BYPASS bit.
3. Flash read current depends on the number of address lines that toggle between sequential Flash read
operations. In most cases, the difference in power is relatively small (on the order of 5%).
4. The Flash memory is organized in rows. Each row in the Si1000/1/2/3/4/5 Flash contains 128 bytes. A
substantial current increase can be detected when the read address jumps from one row in the Flash
memory to another. Consider a 3-cycle loop (e.g., SJMP $, or while(1);) which straddles a 128-byte
Flash row boundary. The Flash address jumps from one row to another on two of every three clock
cycles. This can result in a current increase of up 30% when compared to the same 3-cycle loop
contained entirely within a single row.
5. To minimize the power consumption of small loops, it is best to locate them within a single row, if
possible. To check if a loop is contained within a Flash row, divide the starting address of the first
instruction in the loop by 128. If the remainder (result of modulo operation) plus the length of the loop is
less than 127, then the loop fits inside a single Flash row. Otherwise, the loop will be straddling two
adjacent Flash rows. If a loop executes in 20 or more clock cycles, then the transitions from one row to
another will occur on relatively few clock cycles, and any resulting increase in operating current will be
negligible.
Note: Future 16 and 8 kB derivatives in this product family will use a Flash memory that is organized in rows of 64
bytes each. To maintain code compatibility across the entire family, it is best to locate small loops within a single
64-byte segment.