C8051F360/1/2/3/4/5/6/7/8/9
Table 12.1. Reset Electrical Characteristics
–40 to +85 °C unless otherwise specified.
Parameter
Conditions
= 8.5 mA,
Min
—
Typ
Max
Units
I
OL
RST Output Low Voltage
—
0.6
V
V
= 2.7 V to 3.6 V
DD
0.7 x V
RST Input High Voltage
RST Input Low Voltage
RST Input Pullup Impedance
—
—
—
0.7
—
V
V
DD
—
—
100
2.55
kΩ
V
V
POR Threshold (V
)
RST
2.40
2.70
DD
Missing Clock Detector Time- Time from last system clock
100
40
220
—
600
—
µs
µs
out
rising edge to reset initiation
Delay between release of any
reset source and code
Reset Time Delay
execution at location 0x0000
Minimum RST Low Time to
Generate a System Reset
15
—
—
—
µs
V
Monitor Supply Current
19
40
µA
DD
134