 浏览型号S-35190A-T8T1G的Datasheet PDF文件第19页浏览型号S-35190A-T8T1G的Datasheet PDF文件第20页浏览型号S-35190A-T8T1G的Datasheet PDF文件第21页浏览型号S-35190A-T8T1G的Datasheet PDF文件第22页浏览型号S-35190A-T8T1G的Datasheet PDF文件第24页浏览型号S-35190A-T8T1G的Datasheet PDF文件第25页浏览型号S-35190A-T8T1G的Datasheet PDF文件第26页浏览型号S-35190A-T8T1G的Datasheet PDF文件第27页  
3-WIRE REAL-TIME CLOCK  
S-35190A  
Rev.2.4_00  
Alarm setting of “H (hour)”  
Status register 2 setting  
INT register x alarm enable flag  
AxWE = AxmE = “0”, AxHE = “1”  
Alarm 1 interrupt  
32kE  
= 0, INT1ME = INT1FE = 0  
Alarm 2 interrupt  
None  
INT register 1  
INT register 2  
mx Hx Wx Dx Mx Yx  
Alarm interrupt  
Comparator  
Day of  
Second Minute Hour  
Day Month Year  
the week  
Real-time data  
Real-time data  
H h 00 m 00 s  
01 s  
59 s  
H h 01 m 00 s  
H h 59 m 59 s  
Change by program  
(H  
1) h 59 m 59 s  
(H + 1) h 00 m 00 s  
Change by program Change by program  
Change by program  
INT1AE / INT2AE  
INT pin  
*1  
*1  
Alarm time  
matches*2  
Alarm time matches  
OFF  
OFF  
Period when alarm time matches  
*1. If users clear INT1AE/INT2AE once; “L” is not output from the INT pin by setting INT1AE/INT2AE enable again, within  
a period when the alarm time matches real-time data.  
*2. If turning the alarm output on by changing the program, within the period when the alarm time matches real-time data,  
“L” is output again from the INT pin when the minute is counted up.  
Figure 27 Alarm Interrupt Output Timing (2/2)  
2. Output of user-set frequency  
The output of user-set frequency is the function to output the frequency which is selected by using data, from the INT pin,  
in the AND-form. Set up the data of frequency in the INT register 1.  
Refer to “4. INT register 1 and INT register 2” in „ Configuration of Register”.  
Status register 2 setting  
32kE = 0, INT1AE = Don’t care (0 or 1), INT1ME = 0  
Change by program  
INT1FE  
Free-run output starts  
OFF  
INT pin  
Figure 28 Output Timing of User-set Frequency  