 浏览型号S-35190A-T8T1G的Datasheet PDF文件第14页浏览型号S-35190A-T8T1G的Datasheet PDF文件第15页浏览型号S-35190A-T8T1G的Datasheet PDF文件第16页浏览型号S-35190A-T8T1G的Datasheet PDF文件第17页浏览型号S-35190A-T8T1G的Datasheet PDF文件第19页浏览型号S-35190A-T8T1G的Datasheet PDF文件第20页浏览型号S-35190A-T8T1G的Datasheet PDF文件第21页浏览型号S-35190A-T8T1G的Datasheet PDF文件第22页  
3-WIRE REAL-TIME CLOCK  
S-35190A  
Rev.2.4_00  
„ Power-on Detector and Register Status  
The power-on detection circuit operates by power-on the S-35190A, as a result each register is cleared; each register is set  
as follows.  
Real-time data register :  
Status register 1 :  
Status register 2 :  
INT register 1 :  
00 (Y), 01 (M), 01 (D), 0 (day of the week), 00 (H), 00 (M), 00 (S)  
“01h”  
“01h”  
“80h”  
“00h”  
“00h”  
“00h”  
INT register 2 :  
Clock correction register :  
Free register :  
“1” is set in the POC flag (B0 in the status register 1) to indicate that power has been applied. To correct the oscillation  
frequency, the status register 2 goes in the mode the output of user-set frequency, so that 1 Hz clock pulse is output from  
the INT pin. When “1” is set in the POC flag, be sure to initialize. The POC flag is set to “0” due to initialization so that the  
output of user-set frequency mode is cleared. (Refer to “„ Register Status After Initialization”.)  
For the regular operation of power-on detection circuit, as seen in Figure 22, the period to power-up the S-35190A is that  
the voltage reaches 1.3 V within 10 ms after setting the IC’s power supply voltage at 0 V. When the power-on detection  
circuit is not working normally is; the POC flag (B0 in the status register) is not in “1”, or 1 Hz is not output from the INT pin.  
In this case, power-on the S-35190A once again because the internal data may be in the indefinite status.  
Do not transmit data immediately after power-on at least 0.5 sec because the power-on detection circuit is operating.  
Within 10 ms  
1.3 V  
0 V*1  
*1. 0 V indicates that there are no potential differences between the VDD  
pin and VSS pin of the S-35190A.  
Figure 22 How to Raise the Power Supply Voltage  