Accessories and Spare Parts
For 3RT, 3RH Contactors and Contactor Relays
Accessories for 3RT, 3RH contactors and
contactor relays
For con- Auxiliary
Rated control supply Time setting DT Order No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
Weight
per PU
approx.
1)
tactors
contacts
voltage U
range t
s
Type
V
s
kg
Solid-state time-delay auxiliary switch blocks,
for snapping onto the front, terminal designations
according to DIN 46199, Part 5
Size S00
ON-delay (varistor integrated)
3)
3RT1. 1, 1 NO + 1 NC 24 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
}
}
B
3RT19 16-2EJ11
3RT19 16-2EJ21
3RT19 16-2EJ31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.085
0.084
0.086
2)
3RH11
3RH14
3)
100 ... 127 AC
0.05 ... 1
0.5 ... 10
5 ... 100
C
}
}
D
}
}
3RT19 16-2EC11
3RT19 16-2EC21
3RT19 16-2EC31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.087
0.087
0.086
3)
200 ... 240 AC
0.05 ... 1
0.5 ... 10
5 ... 100
3RT19 16-2ED11
3RT19 16-2ED21
3RT19 16-2ED31
4)
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.088
0.089
0.090
OFF-delay without auxiliary voltage (varistor integrated)
3RT19 16-2....
3)
3RT1. 1, 1 NO + 1 NC 24 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
}
}
}
D
}
B
3RT19 16-2FJ11
3RT19 16-2FJ21
3RT19 16-2FJ31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.087
0.088
0.089
2)
3RH11
3RH14
3)
3)
100 ... 127 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
3RT19 16-2FK11
3RT19 16-2FK21
3RT19 16-2FK31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.086
0.087
0.088
200 ... 240 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
D
}
}
3RT19 16-2FL11
3RT19 16-2FL21
3RT19 16-2FL31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.089
0.089
0.089
OFF-delay with auxiliary voltage
3RT10 1 1 CO
3RH11
24 AC/DC
100 ... 127 AC
200 ... 240 AC
0.5 ... 10
0.5 ... 10
0.5 ... 10
B
B
B
3RT19 16-2LJ21
3RT19 16-2LC21
3RT19 16-2LD21
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.083
0.085
0.085
Wye-delta function (varistor integrated)
2)
3)
3RT10 1 1 NO
delayed +
24 AC/DC
100 ... 127 AC
200 ... 240 AC
1.5 ... 30
1.5 ... 30
1.5 ... 30
}
D
}
3RT19 16-2GJ51
3RT19 16-2GC51
3RT19 16-2GD51
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.086
0.087
0.090
3)
3)
1 NO, instan-
taneous,
dead time
50 ms
Sizes S0 ... S12
With ON-delay
5)
3RT10,
3RT13,
3RT14,
3RT15
1 NO + 1 NC 24 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
D
}
A
3RT19 26-2EJ11
3RT19 26-2EJ21
3RT19 26-2EJ31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.081
0.081
0.082
5)
5)
100 ... 127 AC
0.05 ... 1
0.5 ... 10
5 ... 100
C
}
D
3RT19 26-2EC11
3RT19 26-2EC21
3RT19 26-2EC31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.083
0.083
0.083
200 ... 240 AC
0.05 ... 1
0.5 ... 10
5 ... 100
4)
D
}
B
3RT19 26-2ED11
3RT19 26-2ED21
3RT19 26-2ED31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.085
0.085
0.085
3RT19 26-2....
OFF-delay without auxiliary voltage
5)
3RT10,
3RT13,
3RT14,
3RT15
1 NO + 1 NC 24 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
}
}
}
D
}
C
3RT19 26-2FJ11
3RT19 26-2FJ21
3RT19 26-2FJ31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.085
0.084
0.085
5)
5)
100 ... 127 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
3RT19 26-2FK11
3RT19 26-2FK21
3RT19 26-2FK31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.087
0.086
0.087
200 ... 240 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
D
A
A
3RT19 26-2FL11
3RT19 26-2FL21
3RT19 26-2FL31
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.086
0.084
0.086
Wye-delta function
5)
3RT10,
3RT13,
3RT14,
3RT15
1 NO,
24 AC/DC
1.5 ... 30
1.5 ... 30
1.5 ... 30
}
}
}
3RT19 26-2GJ51
3RT19 26-2GC51
3RT19 26-2GD51
1
1
1
1 unit
1 unit
1 unit
101
101
101
0.084
0.085
0.088
delayed +
1 NO, instan-
taneous,
dead time
50 ms
5)
100 ... 127 AC
5)
200 ... 240 AC
1) The AC voltages are valid for 50 Hz and 60 Hz.
2) Cannot be fitted onto coupling relays.
5) Terminals A1 and A2 for the control supply voltage of the solid-state time-
delay auxiliary switch must be connected to the associated contactor by
means of connecting leads.
3) The terminals for the control supply voltage are connected to the
contactor by the integrated spring contacts of the solid-state time
auxiliary switch above it when this switch is mounted
4) Setting of output contacts in as-supplied state not defined (bistable relay).
Application of the control supply voltage once results in contact
changeover to the correct setting.
* You can order this quantity or a multiple thereof.