3RA13, 3RA14 Contactor Assemblies
3RA13 Reversing Contactor Assemblies
3RA13 complete units, 3 ... 45 kW
Overview
The 3RA13 reversing contactor assemblies can be ordered as
follows:
Sizes S00 to S3
• Fully wired and tested, with mechanical and electrical
interlock (for voltages > 500 V, a dead interval of 50 ms on
reversing must be taken into account)
Sizes S00 to S12
• As components for customer assembly.
Complete units
The fully wired reversing contactor assemblies are suitable for
use in any climate. They are finger-safe according to EN 50274.
The contactor assemblies consist of 2 contactors with the same
power, with one NC contact in the basic unit. The contactors are
mechanically and electrically interlocked (NC contact interlock).
For motor protection, either 3RU11 overload relays for direct
mounting or individual mounting or thermistor motor protection
tripping units must be ordered separately.
Components for customer assembly
Installation kits for all sizes are available for customer assembly
of reversing contactor assemblies.
Contactors, overload relays, the mechanical interlock (as of size
S0) and – for momentary-contact operation – auxiliary switch
blocks for latching must be ordered separately.
3
There is also a range of accessories (auxiliary switch blocks,
surge suppressors, etc.) that must be ordered separately.
For overload relays for motor protection, see "SIRIUS Overload
Relays".
The 3RA13 contactor assemblies have screw connections and
are suitable for screwing or snapping onto 35 mm standard
mounting rails.
Rated data AC-2 and AC-3 for
AC 50 Hz 400 V
Rating
kW
3
4
5.5
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
Operational
current
I
e
A
7
9
12
12
17
25
32
40
50
65
80
95
115
150
185
225
265
300
400
500
Size
Order No.
Contactor
Mechanical
interlock
1)
--
4)
Mechanical
interlock
2)
--
Mechanical
interlock
3)
--
Installation kit
Fully wired and tested
contactor assemblies
3RA13 15-8XB30-1 . .
3RA13 16-8XB30-1 . .
3RA13 17-8XB30-1 . .
3RA13 24-8XB30-1 . .
3RA13 25-8XB30-1 . .
3RA13 26-8XB30-1 . .
3RA13 34-8XB30-1 . .
3RA13 35-8XB30-1 . .
3RA13 36-8XB30-1 . .
3RA13 44-8XB30-1 . .
3RA13 45-8XB30-1 . .
3RA13 46-8XB30-1 . .
--
S00
3RT10 15
3RT10 16
3RT10 17
3RT10 24
3RT10 25
3RT10 26
3RT10 34
3RT10 35
3RT10 36
3RT10 44
3RT10 45
3RT10 46
3RT10 54
3RT10 55
3RT10 56
3RT10 64
3RT10 65
3RT10 66
3RT10 75
3RT10 76
3RA19 13-2A
5)
S0
3RA19 24-1A
3RA19 24-2B
--
3RA19 23-2A
6)
S2
3RA19 24-1A
3RA19 24-2B
--
3RA19 33-2A
7)
S3
3RA19 24-1A
3RA19 24-2B
--
3RA19 43-2A
7)
S6
--
--
3RA19 54-2A
3RA19 53-2A
8)
S10
--
--
3RA19 54-2A
3RA19 63-2A
8)
--
S12
--
--
--
--
3RA19 54-2A
3RA19 73-2A
8)
--
1) Can be mounted onto the front.
2) Laterally mountable with one auxiliary contact.
3) Laterally mountable without auxiliary contact.
4) Interlock can only be ordered with installation kit.
5) Installation kit contains: mechanical interlock; connecting clips for
2 contactors; wiring connectors on the top and bottom.
6) Installation kit contains: wiring connectors on the top and bottom.
7) Installation kit contains: 2 connecting clips for contactors; wiring
connectors on the top and bottom.
8) Installation kit contains: wiring module on the top and bottom.