HDIF45A21Dc SIP5Dc  
3.1 Maximum Rating  
DC voltage  
AC voltage  
VDC  
Vpp  
12  
10  
V
V
Between any terminals  
Between any terminals  
3.2 Electrical Characteristics  
Source impedance  
Load impedance  
ZS=50Ω  
ZL=2kΩ//3pF  
Freq  
TA=25℃  
Min  
10.9  
typ  
max  
Insertion attenuation  
44.06MHz  
12.4  
13.9  
dB  
Reference level  
45.81MHz  
42.23MHz  
41.31MHz  
39.81MHz  
47.31MHz  
4.9  
0.8  
5.9  
1.8  
6.9  
2.8  
17.1  
-
dB  
dB  
dB  
dB  
dB  
dB  
dB  
ppm/k  
Relative attenuation  
14.1  
46.0  
44.0  
36.0  
40.0  
15.6  
54.0  
59.0  
41.0  
47.0  
-72  
-
35.06~39.81MHz  
47.31~55.06MHz  
Temperature coefficient  
Sidelobe  
3.3 Environmental Performance Characteristics  
Item  
High  
temperature  
Condition  
Specifications  
The specimen shall be store at a temperature of  
80±2℃ for 96±4h. Then it shall be subjected to  
standard atmospheric conditions for 1h, after  
which measurement shall be made within 1h.  
The specimen shall be store at a temperature of  
-20±3℃ for 96±4h. Then it shall be subjected to  
standard atmospheric conditions for 1h, after  
which measurement shall be made within 1h.  
The specimen shall be store at a temperature of  
40±2with relative humidity of 90% to 96%  
for 96±4h. Then it shall be subjected to standard  
atmospheric conditions for 1h, after which  
measurement shall be made within 1h.  
Mechanical  
characteristics and  
specifications  
electrical  
characteristics shall  
be satisfied. There  
Low  
temperature  
in  
Humidity  
shall  
be  
no  
excessive change in  
appearance.  
Thermal  
shock  
The specimen shall be subjected to 8 continuous  
cycles each as shown below. Then it shall be  
subjected to standard atmospheric conditions for  
1h, after which measurement shall be made  
within 1h.  
Temperature  
Duration  
1
+25 ℃=>-40 ℃ 0.5h  
www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:info@shoulder.cn  