SAW FILTER  
HDIF38B1Dc SIP5Dc  
3.1 Maximum Rating  
DC voltage  
AC voltage  
VDC  
Vpp  
12  
10  
V
V
Between any terminals  
Between any terminals  
3.2 Electrical Characteristics  
Source impedance  
Load impedance  
Items  
Zs=50Ω  
ZL=2kΩ//3pF  
TA=25℃  
Freq  
Min  
typ  
max  
Insertion attenuation  
Reference level  
dB  
36.50MHz  
14.5  
16.5  
18.5  
38.00MHz  
33.57MHz  
32.50MHz  
31.50MHz  
31.00MHz  
30.00MHz  
39.50MHz  
40.50MHz  
3.6  
5.1  
1.0  
6.6  
2.5  
18.5  
-
dB  
-0.5  
14.5  
17.5  
37.0  
42.0  
42.0  
38.0  
35.0  
35.0  
dB  
16.5  
19.5  
47.0  
52.0  
50.0  
45.0  
47.0  
43.0  
-72  
dB  
dB  
Relative attenuation  
dB  
dB  
dB  
dB  
25.00~30.00MHz  
39.50~45.00MHz  
dB  
Sidelobe  
dB  
Temperature coefficient  
Ppm/k  
3.3 Environmental Performance Characteristics  
Item Condition  
Specifications  
High  
temperature  
The specimen shall be store at a temperature of  
80±2℃ for 96±4h. Then it shall be subjected to  
standard atmospheric conditions for 1h, after  
which measurement shall be made within 1h.  
The specimen shall be store at a temperature of  
-20±3℃ for 96±4h. Then it shall be subjected to  
standard atmospheric conditions for 1h, after  
which measurement shall be made within 1h.  
The specimen shall be store at a temperature of  
40±2with relative humidity of 90% to 96%  
for 96±4h. Then it shall be subjected to standard  
atmospheric conditions for 1h, after which  
measurement shall be made within 1h.  
Mechanical  
characteristics and  
Low  
temperature  
specifications  
electrical  
in  
characteristics shall  
be satisfied. There  
Humidity  
shall  
be  
no  
excessive change in  
appearance.  
Thermal  
shock  
The specimen shall be subjected to 8 continuous  
cycles each as shown below. Then it shall be  
subjected to standard atmospheric conditions for  
1h, after which measurement shall be made  
within 1h.  
www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:info@shoulder.cn  
Page 5 of 10