MA4510
●Standard Operating Condition・Design Standard For Application Circuit
Unit
V
V
Item
Input Rated Voltage
Conditions
Ratings
AC90~132
12
Output Nominal Voltage
Output Nominal Current
2.5
A
●Standard Operating Condition・Standard Operating Characteristics (Ta=25℃)
Ratings
12.0±0.6
12.0±0.6
MAX 3.8
Unit
Item
Minimum Input Full Load Output Voltage
Conditions
Vin=90V, IO=2.5A
Vin=132V, IO=0.25A
Vin=132V, VO=10V
V
V
A
Fig 1, ①ꢀRefer
Fig 1, ②ꢀRefer
Fig 1, ③ꢀRefer
Maximum Input Light Load Output Voltage
Over Current Protection
Foldback Current
Nodamage To Any Device,
Automatic Recovery.
Vin=132V, RO=0.5Ω
-
Fig 1, ④ꢀRefer
Short Circuit
Figure in ○=Terminal Sign
Fig1. Output Voltage/Current
Copyright & Copy;2000 Shindengen Electric Mfg.Co.Ltd