MA3450
●Standard Operating Condition・Design Standard For Application Circuit
Unit
V
W
V
Item
Conditions
Ratings
AC85~132
100
Input Rated Voltage
Output Nominal Wattage
Output Nominal Voltage
Output Nominal Current
24
4.2
A
●Standard Operating Condition・Standard Operating Characteristics (Ta=25℃)
Item Conditions
IO=4.2A, 20.5V≦VO≦24.6V
Ratings
MAX 85
Unit
V
V
V
A
AC Input Voltage
Vin=90V, IO=4.2A
Vin=132V, IO=0.0A
Vin=132V, VO=20V
Minimum Input Full Load Output Voltage
Maximum Input Light Load Output Voltage
24.0±0.6
24.0±0.6
MAX 6.0
Fig 2, ①ꢀRefer
Fig 2, ②ꢀRefer
Fig 2, ③ꢀRefer
Over Current Protection
Foldback Current
Nodamage To Any Device,
Automatic Recovery.
Vin=132V, RO=0.5Ω
-
Fig 2, ④ꢀRefer
Short Circuit
Figure in ○=Terminal Sign
Fig1. Measurement Circuit
Fig2. Output Voltage/Current
Copyright & Copy;2000 Shindengen Electric Mfg.Co.Ltd