SHARP CORPOMITION
ED-94054D
MODEL
No.
1
June
14, 1996
PAGE
PC8 17x
l/8
1. Application
This speciiication applies to the outline and characteristics
Model-No. PC8 17series.
of photocoupler
2. Outline
Refer to the attached drawing No. CY696 lK02.
3. Ratings and characteristics
Refer to the attached sheet, page 3 to 6.
4. Reliability
Refer to the attached sheet, page 7.
5. Incoming inspection
Refer to the attached sheet, page 8.
6. Supplement
6.1 Isolation voltage shall be measured in the following method.
(1) Short between anode to cathode on the primary side and between collector
to emitter on the secondary side.
(2) The dielectric withstand
tester with zero-cross circuit shall be used.
(31 The wave form of applied voltage shall be a sine wave.
(It is recommended that the isolation voltage be measured in insulation
oil.)