6N137
6N137
s
Features
1. Super high speed response
( t
PHL
, t
PLH
: TYP. 45ns at R
L
= 350Ω )
2. Isolation voltage between input and output
V
iso
: 2 500V
rms
3. Low input current drive ( I
FHL
: MAX. 5mA )
4. Instantaneous common mode rejection
voltage
CM
H
: TYP. 500V /
µ
s
5. LSTTL and TTL compatible output
6. Recognized by UL , file No. E64380
s
Applications
1. High speed interfaces for computer
peripherals, microcomputer systems
2. High speed line receivers
3. Noise reduction
4. Interfaces for data transmission equipment
Super High Speed Response
OPIC Photocoupler
s
Outline Dimensions
0.85
±
0.3
8
7
6N137
1.2
6
5
6.5
±
0.5
( Unit : mm )
Internal connection
diagram
8
7
6
5
1
1.2
±
0.3
2
3
4
0.8
±
0.2
1
2
3
4
0.5TYP
Primary side mark ( Sunken place )
9.22
±
0.5
3.7
±
0.5
3.5
±
0.5
7.62
±
0.3
θ
0.5
±
0.1
2.54
±
0.25
θ
θ
=
0 to 13
˚
0.26
±
0.1
1
2
3
4
NC
Anode
Cathode
NC
5
6
7
8
GND
V
O
V
E
V
CC
* “ OPIC ” ( Optical IC ) is a trademark of the SHARP Corporation.
An OPIC consists of a light-detecting element and signal-
processing circuit integrated onto a single chip.
s
Absolute Maximum Ratings
*1
( Ta = 25˚C )
Symbol
I
F
I
FM
V
R
V
CC
C
E
V
OIL
I
OL
P
C
V
iso
T
opr
T
stg
T
sol
Rating
20
40
5
7
5.5
7
50
85
2 500
0 to + 70
- 55 to + 125
260
Unit
mA
mA
V
V
V
V
mA
mW
V
rms
˚C
˚C
˚C
Input
*2
Output
*5
*6
Parameter
Forward current
Peak forward current
Reverse voltage
Supply voltage
Enable voltage
High level output voltage
Low level output current
Output collector
power dissipation
Isolation voltage
Operating temperature
Storage temperature
Soldering temperature
*1 Ta = 0 to 70 ˚C
*2 Pulse width <= 1ms
*3 For 1 minute MAX.
*4 Not exceed 500mV or more than
supply voltage ( V
CC
)
*5 AC for 1 minute, 40 to 60% RH
Apply the specific voltage between all the input
electrode pins connected together and all the
output electrode pins connected together.
*6 2mm or more away from the lead base for 10
seconds
“
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”