Characteristics of Acriche
4. AN3220 (CRI 70)
4-1 Electro-Optical characteristics at 220V/230V Ta=25ºC
Value
Typ
150
Parameter
Symbol
Unit
Min
Max
[2]
[1]
ФV
Luminous Flux
-
-
-
-
-
-
-
-
lm
lx
K
[3]
Фl
CCT
Ra
Illuminance
170
[4]
Correlated Color Temperature
CRI
3000
70
-
mA
[RMS]
Operating Current
Iopt
-
20
-
Power Dissipation
Operating Frequency
View Angle
PD
3.3
50 / 60
110
W
Hz
Freq
2Θ 1/2
deg.
4-2 Absolute Maximum Ratings
Parameter
Symbol
Value
Unit
[5]
Operating Voltage
Power Dissipation
Junction Temperature
Operating Temperature
Storage Temperature
ESD Sensitivity
vopt
PD
253/265
6.4
V [RMS]
W
ºC
ºC
ºC
-
Tj
Topr
Tstg
-
125
-30 ~ +85
-40 ~ +120
±2,000V HBM
*Notes :
[1] Acriche series maintains a tolerance of ±10% on flux and power measurements.
[2] ФV is the total luminous flux output as measured with an integrated sphere.
[3] Illuminance is measured at 50cm distance
[4] Correlated Color Temperature is derived from the CIE 1931 Chromaticity diagram.
CCT ±5% tester tolerance
[5] ‘Operating Voltage' doesn't indicate the maximum voltage which customers use, but it
means tolerable voltage according to the voltage variation rate by one's country.
It is recommended that the temperature of lead frame should be below 70 ℃.
Rev. 03
May 2008
7
www.ZLED.com