BTE2000 / PTE2000 Series
Precision stainless steel pressure transmitters
Specification notes:
IP 65 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through
the connector/cable assembly. Thus the cable end must have access to the ambient pressure.
The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
1.
2.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C.
Long term stability is the change in output after one year or 1 million pressure cycles.
Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
Tests are in accordance with EN61000-6-2, April 1999.
3.
4.
5.
6.
7.
8.
9.
CE-labelling is in accordance with 89/336/EEC.
The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
ELECTROMAGNETIC CAPABILITY7
Test conditions
Criterion Interference
Radiated, radio frequency EN61000-4-3: Grade 3
electromagnetic field
immunity (RFI)
10 V/m, 80 MHz to 1000 MHz
80 % AMC (1 kHz)
EN61000-4-4: Grade 3
A
<1 % FSO
Electrical fast transient /
burst immunity (EFT)
B
B
<1 % FSO
<1 % FSO
±2 kV
Electrostatic discharge
immunity test (ESD)
EN61000-4-2: Grade 4
±8 kV, contact discharge
EN61000-4-6: Grade 3
0,15 to 80 MHz
10 V, 80 % AMC (1 kHz)
Immunity to conducted
disturbances induced by
radio-frequency fields
A
<1 % FSO
OUTPUT CHARACTERISTIC
1...6 V output version
4...20 mA output version
6
20
Iout
Vout
5
16
mA
12
V
4
3
2
1
8
4
0
20
40
60
80
100
0
20
40
60
80
100
% full scale pressure
% full scale pressure
December 2008 / 098
3/6